Alignment of Unit
56
SafEye
TM
Xenon 700S Gas Detector User Guide
Notes:
To ensure proper alignment according to factory calibration, prior to
telescope installation, verify that the telescope and its sight mounting
are free of dirt.
To ensure optimal alignment, do not attempt to change factory
calibration of the telescope or its mounting.
To align the unit (see Figure 10):
1
Ensure that the detector and the flash source are installed
properly. Installation instructions are described in Installation
Instructions, page 43.
2
Install the telescope assembly (Item 12) on the telescope site
mounting of the source according to the drawing. Fasten the
telescope with fastening screws (Item 13).
3
Crude alignment:
Use ¼” Allen screw driver for all alignment screws.
Loosen screws 5 and 6.
Approximately aim the source horizontally toward the detector.
Tighten screw 6.
Loosen screws 3 and 4.
Approximately aim the source vertically toward the detector.
Tighten screw 3.
4
3 for the detector towards the source.
5
Fine Alignment:
Aim the source to the detector within horizontal axis using
screw 7. Aim the telescope cross toward the front level of the
telescope site or the detector.
6
Tighten screw 5.
7
Aim within the vertical axis using screw 8.
8
Tighten screw 4.
9
Make sure the telescope cross is pointing to the center of the
detector and source window.
10
5 for the detector alignment.
Содержание SafEye Xenon 700S
Страница 2: ...This page intentionally left blank ...
Страница 12: ......
Страница 16: ......
Страница 24: ...Models and Types 24 SafEyeTM Xenon 700S Gas Detector User Guide Figure 1 Wiring Options ...
Страница 64: ......
Страница 72: ......
Страница 76: ......
Страница 79: ...This page intentionally left blank ...