SpectraPure
SpectraPure®Inc.
480.894.5437 Call us toll-free 1.800.685.2783
215 South Industrial Drive, Suite 2A Tempe, Arizona 85281-2941
®
22
Tips for Long Membrane Life
1. Replacement of 1 micron sediment filter once every 6 months.This will pre
vent mem brane fouling due to silt or sediment depositing on the membrane.
2. Replacement of 10 micron carbon block filter at least once every 6 months
or when chlorine breakthrough occurs . This will ensure good membrane life
and protect the membrane from chlorine damage.
3. Membrane should not be operated at lower than the recommended concen
trate to purified water ratios, as described on page 6.
4. Operating reverse osmosis systems on softened feed water greatly reduces
the chances of membrane fouling.
5. Use the optional flush kit valve after each use of the system to extend
membrane life up to 6 months.
Storage
1. It is recommended that you store your Eliminator RO System in a cool
place when not being used.
2. Your Eliminator RO System must be protected from freezing or temperatures
above 100° F (38°C).
Choosing a Mounting Location
When considering a location for the installation of the System, consider the
following factors:
Light
Sources
1. Most of the components of this system are plastic and are subject to
damage by ultra- violet light from the sun and other sources such as metal
halide lighting.
2. Algae is more likely to thrive inside the clear filter housings when exposed to
bright
light.
3. Avoid installing this unit in bright light or direct sunlight.
Temperature
Extremes
1. The unit must be kept out of areas that are subject to freezing temperatures.
2. High temperatures greater than 100° F (38° C) must be avoided. If the unit is
used outside, avoid putting the system in direct sunlight or connecting it to a
garden hose that may be exposed to sunlight.
System Care
SpectraPure
®
SpectraPure®Inc
.
Fax 480.894.6109 Fax us toll-free 1.877.527.7873
E-mail: [email protected] Visit us on the web www.spectrapure.com
3
System Specifications
Sediment Pre-Filter
1 micron MicroTec™ sediment pre-filter
Carbon Filter
1 micron carbon block pre-filter
RO Membrane Type
Encapsulated thin-film composite
DI
Cartridge
SilicaBuster™ Color-Indicating Mixed-Bed
Rejection Rate
Greater than 98% average
Input Water Pressure
60 psi (4.15 bar) line pressure*
Input Water Temp
77°F (25°C)
Recovery Rate
20% (i.e. 20% of the water will be
collected
as
pure
water)
Nominal Membrane Flow Rates @ 60 psi, 77° F, & 500 ppm TDS :
GPD (lpd) Product Water Flow Rate
Concentrate Flow Rate
90
(340)
235
ml/min
940
ml/min
180 (680)
470 ml/min
1880 ml/min
Reverse Osmosis Membrane Feed Water
Requirements
Operating Pressure*
40 – 80 psi (2.75 – 5.5 bar)
pH
Range
3
–
11
Temperature Range
38°F – 100° F (3°C – 38°C)
Maximum
Turbidity
1.0
NTU
Maximum Silt Density Index
5.0 (based on 15 min. test time)
Maximum Chlorine
less than 0.1 ppm
Maximum
TDS
2000
ppm
Maximum Hardness
10 grains (170 ppm as CaCO3)
Maximum
Iron
less
than
0.1
ppm
Maximum Manganese
less than 0.1 ppm
Maximum Hydrogen Sulfide
0 ppm
Langlier Saturation Index
LSI must be negative
*Operating pressure less than 40 psi will require a high flow booster
pump (BPHF-MO-115(230)).
*Operating pressure greater than 80 psi will require a pressure reducing
valve.
System Information