background image

SpectraPure

SpectraPure®Inc.

  

480.894.5437   Call us toll-free  1.800.685.2783    

215 South Industrial Drive,   Suite 2A   Tempe, Arizona   85281-2941

®

8

Fig. C: Single-Membrane Assembly

Top/Rear View

membrane 

feed 

push-fitting

black 

tubing to 

membrane 

feed

RO membrane

yellow concentrate tubing

blue purified 

water tubing
black feed 

tubing

yellow tubing

capillary tubing 

plastic insert

Fig. E:  Flow Restrictor Assembly 

System Set-Up

Fig. D: Dual-Membrane Assembly

Top/Rear View

blue purified 

water tubing

Membrane 2

concentrate 

push-fitting

yellow concen-

trate tubing

Membrane 1

feed push

 fitting

black membrane 

feed tubing

mounting 

bracket

Membrane 1

Membrane 2

product water tee 

carbon filter output 

push-fitting

blue product water 

interconnect 

tubing
Membrane 2

feed push-fitting

black interconnect

feed tubing
Membrane 1 concen-

trate push-fitting

Membrane 1 prod-

uct water push 

fitting

black feed tubing

SpectraPure

®

SpectraPure®Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

17

System Maintenance

 

7.  Depress the collar on the Membrane 1 product water push 

 

 

fitting with your thumbnail and remove the blue product water inter- 

  connect 

tubing.

 

8.  Depress the collar on the Membrane 2 product water push 

 

 

fitting with your thumbnail and remove the blue product water inter- 

  connect 

tubing.

 

9.  Lift the dual RO membrane assembly from the holding clips.

 

10.  Separate the two membranes by depressing the collar on the push 

 

 

fitting of the concentrate push-fitting on Membrane 1 and pulling the  

 

 

two membranes apart (see Fig. G).

 

11.  Remove the black interconnect feed tubing that remains connected to

  Membrane 

2.

 

12.  Remove the double clips from both membranes.

 

13.  Discard the two spent membranes.

 

Note:   Insert all tubing into their respective push-fittings using the follow

   ing 

directions:

 

 

 

a.)  Moisten the o-ring seal inside the push-fitting by dripping a few 

 

 

 

drops of clean water into the fitting. 

 

 

 

b.)  Grasp the tubing near the end, and insert the tubing into the

 

 

 

push-fitting. Push the tubing into the fitting until resistance is felt - 

 

 

 

approximately 1/2 inch (12.7 mm). The tubing is now resting on the

 

 

 

O-ring seal inside the fitting.

 

 

 

c.)  Now firmly push the tubing approximately an additional 1/4 

 

 

 

inch (6.35mm) further into the fitting to completely seat the line into 

 

 

 

the fitting and O-ring seal.

 

14.  Insert the black interconnect feed tubing into one of the new replace

 

 

ment membranes, which will now be designated as Membrane 2.

 

15.  Re-attach the two clips to Membrane 2.

 

16.  Align and inset the black interconnect feed tubing into the concentrate

 

 

push-fitting of the other membrane, which is now designated as 

  Membrane 

1.

 

17.  Clamp the two membranes together.

 

18.  Re-attach one blue tubing to Membrane 1 and then the other blue 

 

 

tubing to Membrane 2.

Содержание The Eliminator DI

Страница 1: ...f membrane elements for one year from date of receipt by the buyer providing that the loss of performance was not caused by fouling neglect or water conditions exceeding the feed water parameters list...

Страница 2: ...ane 19 20 Membrane Testing System Troubleshooting Guide 21 Membrane Troubleshooting Guide 21 System Care Tips for Long Membrane Life 22 Storage 22 Choosing a Mounting Location 22 System Components Rep...

Страница 3: ...Temperature Extremes 1 The unit must be kept out of areas that are subject to freezing temperatures 2 High temperatures greater than 100 F 38 C must be avoided If the unit is used outside avoid puttin...

Страница 4: ...Low water temperature Heat feed water or use higher GPD membrane Low feed pressure Use booster pump or use higher GPD membrane Fouled membrane Replace membrane Membrane Troubleshooting Guide The follo...

Страница 5: ...3 X Y 143 ppm 4 X Y X 143 150 0 953 5 Rejection X Y X 100 0 953 100 95 3 Membrane Hardness Rejection 95 3 Membrane OK Production Rate SpectraPure SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 87...

Страница 6: ...illiliters per Minute 5 If the actual concentrate flow rate is less than the optimum concentrate flow rate you must reduce the length of the flow restrictor capillary tubing as described on the next p...

Страница 7: ...ncentrate tubing Fig C for Single Membrane System or Fig D for Dual Membrane System Remove the tubing from its push fitting at the membrane as follows a Firmly depress and hold the push fitting collar...

Страница 8: ...ail and remove the blue product water inter connect tubing 9 Lift the dual RO membrane assembly from the holding clips 10 Separate the two membranes by depressing the collar on the push fitting of the...

Страница 9: ...mbrane 1 Membrane 2 feed push fitting black inter connect feed tubing blue product water interconnect tubing Membrane 1 concentrate push fitting Membrane 1 product water push fitting SpectraPure Spect...

Страница 10: ...raPure SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com 15 Note The flow restrictor assembly should remain uninst...

Страница 11: ...as described in the Removal Adjustment and Replacement section on page 7 Snap the membrane assembly back into its holding clips System Maintenance RO Membrane Replacement If you have a Single Membran...

Страница 12: ...and check for leaks System Maintenance SpectraPure SpectraPure Inc Fax 480 894 6109 Fax us toll free 1 877 527 7873 E mail spectra spectrapure com Visit us on the web www spectrapure com 13 System Mai...

Отзывы: