OPTIONAL INSTALLATION FOR WASTE WATER LINE (USING A DRAIN SADDLE)
CHECK BEFORE LEAVING SYSTEM UNATTENDED:
-
Ensure that all fittings are tight and leak-free before leaving the system unattended.
-
The concentrate line (yellow) includes a smaller capillary tube (flow restrictor) that is located “inside”
of the tubing. Do not remove or discard this restrictor; the system will not produce permeate water
without the flow restrictor.
-
The following conditions must be met before water can be produced: The water source must be
turned “ON” and the water level in the reservoir tank must be below the low level float.
STEP 10: FINAL CONNECTION:
A. Direct the waste line (yellow ) to a drain or connect it permanently to a drain pipe via
a Drain Saddle. (Drain Saddle is not included with system.)
B.
Inspect for leaks and do not leave the system alone until you are sure there are
no leaks. Monitor the system for 72 hrs.
SETUP PROCEDURES (continued)
CAUTION
An extremely long drain line may create a siphon which will pull the water past the 4# check valve
and cause water to drain from the tank after shutdown. The following solution assumes that you
have already installed the system above the tank.
Route the yellow 1/4” waste water line up above the system as high as possible. Run a 1/2" drain pipe
(or a garden hose) from the drain location up vertically to the elevated yellow 1/4" waste water line.
Insert the waste water line down into the 1/2" drain line a few inches to create a “siphon break”.