STEP 9: CONNECT BULKHEAD FITTINGS:
(Bulkhead Fittings MUST be installed on the same container that the floats are on, SEE DIAGRAM ON PAGE 7)
1/4" BULKHEAD FITTING: Use a paddle bit and carefully drill a 5/8” hole for installation at
the top of the reservoir (above the high level float).
3/8" BULKHEAD FITTING: Use a paddle bit and carefully drill a 13/16" hole for installation
at the bottom of the reservoir (below the low level float).
(continued on next page)
Left-Hand
METER #1
IN: Tap Water
OUT: RO Water
Right-Hand
METER #2
IN: MaxCap
®
Water
OUT: SilicaBuster
™
Water
SETUP PROCEDURES (continued)