12. Turn off the water supply to the system. Remove the yellow
tubing from the membrane housing and replace the flow restrictor
assembly as described on page 9-10.
13. Re-insert the flow restrictor end of the yellow tubing into
its push-fitting at the RO membrane and reconnect the yellow
concentrate tubing to the membrane housing.
14. Turn on the water supply to the system and check for leaks. Check,
and if necessary adjust, the Waste to Product Water Ratio per
the procedures described on page 6-10.
Fig. F: Removing the Membrane Element
Fig. G: Inserting the New Membrane Element
black
membrane
brine seal
black
membrane
housing O-
ring
membrane
product
water tube
double O-
ring end of
membrane
product
water stem
tube