1. Replacement of 1 micron sediment filter once every 6
months. This will prevent mem brane fouling due to silt or
sediment depositing on the membrane.
2. Replacement of 1 micron carbon block filter at least once
every 6 months or when chlorine breakthrough occurs. This
will ensure good membrane life and protect the membrane
from chlorine damage.
3. Membrane should not be operated at lower than the
recommended concentrate to purified water ratios.
4. Operating reverse osmosis systems on softened feed
water greatly reduces the chances of membrane fouling.
5. Use the optional flush valve kit after each use of
the system to extend membrane life.
1. It is recommended that you store your RO System in a cool place
when not being used. (a Flush Valve Kit is recommended for
manually operated systems)
2. If your system is exposed to sunlight you will grow algae in the
housing and it may damage your system.
3. Your RO System must be protected from freezing or temperatures
above 100° F (38°C).
4. MEMBRANE WARNING: All SpectraPure RO membranes, except for
encapsulated membranes, must remain moist at all times. It is the
customer’s responsibility to inspect the membrane upon receipt and
maintain adequate moisture.
Replacement membranes should be kept in the sealed non-permeable
shipping bag and in a refrigerator until use. The membrane can be kept
there for up to 1 year.
(DO NOT FREEZE)
TIPS FOR LONG MEMBRANE LIFE:
STORAGE: