6. Re-insert the yellow tubing into its push-fitting in the RO membrane
as follows:
a.) Moisten the O-ring seal inside the concentrate outlet fitting
by dripping a few drops of clean water into the fitting.
b.) Grasp the yellow tubing near the flow restrictor end, and
insert the tubing into the push-fitting. Push the tubing into
the fitting until resistance is felt, approximately 1/2 inch
(12.7 mm). The tubing is now seated on the O-ring seal
inside
the
fitting.
c.) Firmly push the tubing approximately an additional 1/4 inch
6.35 mm) further into the fitting to completely seat the line
into the fitting and O-ring seal.
7. Turn on the system’s water supply and check for leaks prior to further
use or testing. If a leak is observed, you may not have pushed the
yellow tubing into the push-fitting far enough to seal the tubing
against the O-ring. Turn off the system water supply and re-seat the
tubing as described above.
YELLOW TUBING:
(Disconnected
from membrane
housing’s fitting.
)
CAPILLARY TUBE:
(Specific diameters are
matched for each size
membrane to restrict
the flow of waste
water leaving the RO
membrane’s housing.)
PLASTIC INSERT: (Insert keeps
capillary tube in the yellow line and
prevents it from washing down the
drain. It also forces waste water to
flow through the capillary tubing to
restrict waste water as it leaves the
housing.)
Fig. D: Flow Restrictor Assembly