Reverse Osmosis Water Purification System

(Single and Dual Membrane Models)

The MarinePRO

™ 

DI System

INSTALLATION AND OPERATING 

MANUAL

WARNING

Please read carefully before proceeding with installation. Failure to 

follow any attached instructions or operating parameter may lead to 

the product’s failure and possible damage to property.

Содержание MarinePRO DI System

Страница 1: ... Membrane Models The MarinePRO DI System INSTALLATION AND OPERATING MANUAL WARNING Please read carefully before proceeding with installation Failure to follow any attached instructions or operating parameter may lead to the product s failure and possible damage to property ...

Страница 2: ...Systems Basic Parts Metering Diagnostics 11 Filter Diagnostics Sediment Filter Diagnostic 12 Carbon Filter Diagnostic 13 Deionization Cartridge Diagnostic 14 RO Membrane Diagnostic 15 17 Troubleshooting Guide Troubleshooting Guide 18 21 Tips Storage 22 Replacement Optional Parts 23 Warranty 24 COPYRIGHT 2002 2009 BY SPECTRAPURE INC ALL RIGHTS RESERVED TABLE OF CONTENTS Thank You for your purchase ...

Страница 3: ... 100 340 235ml min 940 ml min 200 680 470ml min 1880 ml min Reverse Osmosis Membrane Feed Water Requirements For the 1 year SpectraSelect TFC membrane pro rated warranty to be honored the following conditions must be met Operating Pressure 40 80 psi 2 75 5 5 bar pH Range 3 11 Maximum Temperature 100 F 38 C Maximum Turbidity 1 0 NTU Maximum Silt Density Index 5 0 based on 15 min test time Maximum C...

Страница 4: ...d Bed Multi Layer They are capable of producing 18 meg ohm cm resistivity water They are the first DI cartridges designed to reduce silica nitrates and phosphate levels in the low ppb range These newly formulated cartridges far exceed the performance of previous cartridges offering enhanced contaminant removal longer life and higher purity Caution The deionization cartridge life is greatly reduced...

Страница 5: ... tubing and the blue purified product water tubing into a drain Do not restrict flow from these lines 3 Open the cold water supply valve You may use pressure up to 80 psi 5 5 bar Check the system to ensure that all fittings are tight and leak free before leaving the system unattended If anything is leaking contact SpectraPure for assistance Note It is recommended that at least 2 gallons 7 57 liter...

Страница 6: ... of 4X the product flow rate 4X to 6X is an acceptable concentrate flow rate Procedure 1 Collect product water blue tubing into a measuring cup for one minute Measure the collected amount in milli liters Do the same with the waste water yellow tubing WASTE YELLOW IN MILLILITERS______________ DIVIDED BY PRODUCT BLUE IN MILLILITERS______________ The resultant is the Concentrate to Product Ratio Alth...

Страница 7: ...175 67 6 15 2 164 62 7 17 8 154 58 8 20 3 148 56 9 22 9 141 54 10 25 4 136 52 11 27 9 133 50 12 30 5 129 49 13 33 0 128 48 14 35 6 124 47 15 38 1 124 47 16 40 6 PRODUCT RATE CUT TO LENGTH 80 ml min gpd in cm 490 186 1 2 5 460 175 2 5 1 430 163 3 7 6 400 152 4 10 2 379 144 5 12 7 356 135 6 15 2 344 131 7 17 8 326 124 8 20 3 311 118 9 22 9 300 114 10 25 4 289 110 11 27 9 281 107 12 30 5 270 103 13 3...

Страница 8: ... us toll free 1 800 685 2783 2167 East Fifth St Tempe Arizona 85281 8 SINGLE MEMBRANE SYSTEM FIG B DUAL MEMBRANE SYSTEM FIG C 1 4 BLACK LINE Tap Water 1 4 BLUE LINE Product Water 1 4 YELLOW LINE Waste Water Flow Restrictor is inside the Waste line ...

Страница 9: ...ollar and thin capillary tubing may then be gently extracted Note Take care not to crush or otherwise damage the delicate capillary tubing 3 Refer to the Flow Restrictor Tables Fig A Find the table that represents the Flow Restrictor Assembly for the system that you have Find the product flow rate in the left hand column and the length of the flow restrictor in the right hand column Example If you...

Страница 10: ...5 mm further into the fitting to completely seat the line into the fitting and O ring seal 7 Turn on the system s water supply and check for leaks prior to further use or testing If a leak is observed you may not have pushed the yellow tubing into the push fitting far enough to seal the tubing against the O ring Turn off the system water supply and re seat the tubing as described above YELLOW TUBI...

Страница 11: ...re As the filters collect particulates the pressure will begin to drop A 15 20 drop in pressure would indicate that the pre filters are in need of replacement OPTIONAL TDS METER FOR MEMBRANE DI TESTING You can purchase an optional Dual TDS Meter MTR TDS DL1 to determine when the Membrane DI Cartridge needs to be replaced Or you can follow 2 simple rules As the hardness of the water builds up on th...

Страница 12: ...eplaced If you remove the sediment and the pressure does not return to normal the carbon filter may be plugged Sediment Pre Filter Replacement Materials Required 1 micron MicroTec Sediment Filter SF MT 1 10 Filter Wrench Procedure 1 Turn off water supply to the system 2 Refer to Fig B System Diagram Using the provided filter housing wrench remove the first housing on the left Unscrew it counterclo...

Страница 13: ...but a carbon filter can also drop production if its covered with extremely fine sediment If the carbon becomes plugged with sediment it will no longer be able to remove chlorine Carbon Block Filter Replacement Materials Required 1 micron Carbon Block Filter CF 1 10 Filter Wrench Chlorine Test Kit TK CL 25 Procedure 1 Turn off water supply to the system 2 Refer to Fig B System Diagram Using the pro...

Страница 14: ...moved Thus seeing a larger TDS reading out of the DI than you would out of the RO membrane Materials Needed One DI SB CI 10 Deionization cartridge filter wrench Procedure 1 Remove the filter housing from its cap by unscrewing it counter clockwise as viewed from the bottom 2 Remove and discard the old cartridge from the housing 3 Thoroughly wash out the housings with hot soapy water to which a few ...

Страница 15: ...e the TDS of your tap water See page 9 for removal of push fittings on tee 3 Slowly turn the tap water on and direct the stream to a drain After you get a good flow coming out of the end of the tee you can test the water TAP WATER TDS READING _______________ 4 Once you obtain the tap water TDS reading reconnect the IN Probe back to its original location 5 Connect the BLACK line back to the first s...

Страница 16: ...When the membrane is aligned with the hole firmly push the membrane into the hole until it bottoms out 8 Place the black housing O ring on the housing rim and carefully screw the lid back on to the base 9 Reconnect the black tubing to the membrane feed push fitting Note If you have a dual membrane system perform steps 2 thru 9 on the second membrane now See page 8 Fig C for tubing re connection IF...

Страница 17: ...flow restrictor end of the yellow tubing into its push fitting at the RO membrane and reconnect the yellow concentrate tubing to the membrane housing 14 Turn on the water supply to the system and check for leaks Check and if necessary adjust the Waste to Product Water Ratio per the procedures described on page 6 10 Fig F Removing the Membrane Element Fig G Inserting the New Membrane Element black ...

Страница 18: ...ressure reducing valve 4 Red light on purity monitor comes on a Exhausted deionization cartridge i Replace cartridge b Bad membrane exhausted cartridge ii Replace membrane deionization cartridge c Faulty monitor probe iii Replace monitor probe 5 Pressure gauge does not register anything a Missing flow restrictor i Put flow restrictor in the yellow line b Pressure gauge screwed in too far ii Unscre...

Страница 19: ...ed pressure Note The membrane is rated to produce the rated GPD at 60 psi For any pressure other than 60 psi the output GPD is multiplied by the PCF PCF Line Pressure in psi 60 Calculation of Temperature Correction Factor TCF The output GPD also decreases with decrease in temperature This is because water viscosity increases with decrease in water temperature Temperature Correction Factor Table TC...

Страница 20: ...r TDS Total Dissolved Solids Important Test the quality of the membrane once every 6 months Procedure 1 Measure tap water TDS Call it X 2 Run the system for 15 20 minutes 3 Measure RO water s TDS Call it Y 4 Subtract RO water TDS from tap water TDS X Y 5 Divide this quantity by tap water TDS X Y X 6 Rejection X Y X 100 Rejection of the RO Membrane Calculation Example 1 Tap water TDS 150 ppm X 2 RO...

Страница 21: ... vary significantly Method of Calculate Test Results Conclusion Testing Rejection TDS Measure feed water and Is Rejection No Replace Membrane Conductivity RO product water TDS greater than Yes Membrane OK Tester Conductivity 95 Alkalinity Measure feed water and Is Rejection No Replace Membrane Test Kit RO product water greater than Yes Membrane OK Alkalinity 90 Hardness Measure feed water Is Rejec...

Страница 22: ...e fouling 5 Use the optional flush valve kit after each use of the system to extend membrane life 1 It is recommended that you store your RO System in a cool place when not being used a Flush Valve Kit is recommended for manually operated systems 2 If your system is exposed to sunlight you will grow algae in the housing and it may damage your system 3 Your RO System must be protected from freezing...

Страница 23: ...low Restrictor for 100 gpd 340 lpd System FR 200 Flow Restrictor for 200 gpd 680 lpd System DI SB CI 10 SilicaBuster Color Change DI Cartridge GHA 4 1 4 6 35 mm Garden Hose Adapter WR UNIV Filter Wrench OPTIONAL ACCESSORIES Model Optional Part FAU SMP Quick Connect Faucet Coupler TK CL 25 Total Chlorine Test Kit TS C61 Conductivity micro Siemens Tester TS T71 TDS Total Dissolved Solids Tester VA F...

Страница 24: ...ctraSelect RO membrane elements only for one year from date of receipt by the buyer providing that the loss of performance was not caused by fouling neglect or water conditions exceeding the feed water parameters listed in the applicable product manual refer to detailed membrane warranty information SpectraPure will on confirmation of loss of performance during the warranty period credit the pro r...