background image

SpectraPure

®

Inc

 Fax  480.894.6109 Fax us toll-free 1.877.527.7873

E-mail: [email protected] Visit us on the web www.spectrapure.com

19

SpectraPure

®

THREE-YEAR LIMITED WARRANTY:                                          

All standard water purification products manufactured by SpectraPure have a 3 year limited 
warranty, except the Eliminator™ MarinePro™, Industrial, Laboratory, Custom Systems, Commercial 
and electrical products which have a 1 year limited warranty. LiterMeters™ & UPLC™ have a 5 year 
limited warranty. OEM equipment resold by SpectraPure (pumps and monitors) carry the original 
manufacturer’s warranty. 
SpectraPure, Inc.

®

 warrants the product to the original owner only to be free of defects in material 

and workmanship for a period of three years from the date of receipt. SpectraPure’s liability under 
this warranty shall be limited to repairing or replacing at SpectraPure’s option, without charge, 
F.O.B. SpectraPure’s factory, any product of SpectraPure’s manufacture. SpectraPure will not be 
liable for any cost of removal, installation, transportation or any other charges which may arise in 
connection with a warranty claim. Products which are sold but not manufactured by SpectraPure 
are subject to the warranty provided by the manufacturer of said products and not by SpectraPure’s 
warranty. SpectraPure will not be liable for damage or wear to products caused by abnormal 
operating conditions, accident, abuse, misuse, unauthorized alteration or repair or, if the product 
was not installed in accordance with SpectraPure’s or other manufacture’s printed installation and 
operating conditions, or damage caused by hot water, freezing, flood, fire or acts of God. 
SpectraPure will not be responsible for any consequential damages arising from installation or use 
of the product, including any water or mold damage due to flooding which may occur due to 
malfunction or faulty installation, including, but not limited to failure by installer to over- or under-
tighten fittings, housings, and/or push-style fittings, or improper installation of push-style fittings. 
Consumable items such as prefilters and membranes are not covered under the 3 year warranty.
SpectraPure warrants (prorated) the performance of tested SpectraSelect™ RO membrane elements 
only, for one year from date of receipt by the buyer, providing that the loss of performance was not 
caused by fouling, neglect or water conditions exceeding the feed water parameters listed in the 
applicable product manual (refer to detailed membrane warranty information). SpectraPure will, 
on confirmation of loss of performance during the warranty period, credit the prorated amount 
of the current catalog price of the element. The disposable filters and  cartridges are not covered 
under the warranty.
To obtain service under this warranty, the defective system or components must be returned to 
SpectraPure with proof of purchase, installation date, failure date and supporting installation data. Any 
defective product to be returned to the factory must be sent freight prepaid; documentation supporting 
the warranty claim and a Return Goods Authorization (RMA) number must be included. SpectraPure 
will not be liable for shipping damages due to the improper packaging of the returned equipment and 
all returned goods must also have adequate insurance coverage and a tracking number. 
SpectraPure will not pay for loss or damage caused directly or indirectly by the presence, growth, 
proliferation, spread or any activity of “fungus”, wet or dry rot or bacteria. Such loss or damage is 
excluded regardless of any other cause or event that contributes concurrently or in any sequence 
to the loss. We will not pay for loss or damage caused by or resulting from continuous or repeated 
seepage or leakage of water, or the presence or condensation of humidity, moisture or vapor, that 
occurs over a period of 14 days or more. “Fungus” and “fungi” mean any type or form of fungus or 
Mycota or any byproduct or type of infestation produced by such fungus or Mycota, including but 
not limited to, mold, mildew, mycotoxins, spores, scents or any biogenic aerosols. 
SpectraPure will not be liable for any incidental or consequential damages, losses or expenses 
arising from installation, use, or any other causes. There are no expressed or implied warranties, 
including merchantability or fitness for a particular purpose, which extend beyond those warranties 
described or referred to above.

* The three year limited warranty does not apply to consumable items, including but 

not  limited to, filters and cartridges unless specifically stated above.

Содержание CR-RODI-90-10

Страница 1: ...em INSTALLATION AND OPERATING MANUAL WARNING Please read carefully before proceeding with installation Failure to follow any attached instructions or operating parameter may lead to the product s failure and possible damage to property CR RODI 90 10 ...

Страница 2: ...n and Initialization 7 8 Metering and Diagnostics Using the Pressure Gauge 9 Using the Three Probe TDS Meter 9 Membrane Output Calculation 10 11 Membrane Rejection Test 11 System Maintenance Sediment Prefilter Replacement 12 Carbon Block Prefilter Replacement 12 Deionization Cartridge Replacement 13 RO Membrane Replacement 14 15 System Storage and Troubleshooting Membrane Troubleshooting Guide 16 ...

Страница 3: ... Membrane Flow Rates 60 psi 77 F 500 ppm TDS GPD Product Water Flow Rate Concentrate Flow Rate 3 1 90 236 ml min 708 ml min Reverse Osmosis Membrane Feed Water Requirements For the 1 year SpectraPure TFC membrane prorated warranty to be honored the following conditions must be met Operating Pressure 40 80 psi 2 75 5 5 bar pH Range 3 11 Maximum Temperature 113 F 45 C Maximum Turbidity 1 0 NTU Maxim...

Страница 4: ... removes on average 98 of most inorganic salts all microorganisms and almost all high molecular weight organics in the water 5 The fifth stage moves water through a SilicaBuster Mixed Bed Multi Layer Deionization Cartridge SilicaBuster Deionization Cartridges are fabricated with semiconductor grade resins for the highest possible purity water They are capable of producing 18 megohm cm resistivity ...

Страница 5: ...roduct Water 1 4 YELLOW LINE Waste Water Flow Restrictor is inside the Waste line SpectraPure Inc assumes no responsibility for water damage due to leaks It is the user s responsibility to determine that the system is leak free Membrane feed push fitting Black tubing to membrane feed RO membrane inside housing Yellow concentrate waste tubing Union Connector Blue purified water tubing Good Water Re...

Страница 6: ...sh fitting by dripping a few drops of clean water into the fitting 2 Grasp the tubing near the end and insert the tubing into the push fitting 3 Push the tubing into the fitting until resistance is felt approximately 1 2 inch 12 7 mm The tubing is now resting on the O ring seal inside the fitting 4 Firmly push the tubing approximately an additional 1 4 inch 6 35 mm further into the fitting to comp...

Страница 7: ... connecting it to a garden hose that may be exposed to sunlight 4 Attach the black tap water tubing to the left side of the Sediment Filter Housing See IN Port on page 4 5 Attach the yellow drain line to the union connector at the rear of the system This connector already has a red tube attached to it 6 Attach the blue product line to the front port after the tee of the right hand DI housing See i...

Страница 8: ...t be kept purged from the housings by slightly unscrewing the housing and letting the running water displace the air until the housing is full of water When full hand tighten the housing 17 Set the meter to Line 3 and run the system until the meter reads zero The water is now ready to use You can set the meter to monitor either of the 3 probes at any time Line 1 displays the Tap Water TDS Line 2 d...

Страница 9: ...TDS METER TRM 1 METER The digital TDS meter three probe will provide a reliable means of evaluating the performance of the RO membrane and the Deionization Cartridge The numbers from the three probe readings can be used to calculate the percentage of rejection of the RO membrane and the exhaustion point of the DI Cartridge Procedure for testing the RO Membrane 1 Follow the instructions on page 11 ...

Страница 10: ...tional to the applied pressure NOTE The membrane is rated to produce the rated GPD at 60 psi For any pressure other than 60 psi the output GPD is multiplied by the PCF PCF Line Pressure in psi 60 Calculation of Temperature Correction Factor TCF The output GPD also decreases with decrease in temperature This is because water viscosity increases with decrease in water temperature Temperature Correct...

Страница 11: ... by its ability to reject salts or TDS Total Dissolved Solids Important Test the quality of the membrane once every 6 months Procedure 1 Set meter to Line 1 and read tap water TDS Call it X 2 Run the system for 15 20 minutes 3 Set meter to Line 2 and read RO water TDS Call it Y 4 Subtract RO water TDS from tap water TDS X Y 5 Divide this quantity by tap water TDS X Y X 6 Rejection X Y X 100 Reject...

Страница 12: ...ew teaspoons of household bleach Rinse well with clean hot water 5 Install the new prefilter onto the round port in the head of the housing Screw the housing back onto the assembly and hand tighten only NOTE Do not use filter wrench to tighten housings Over tightening will damage housings and void your warranty 6 Proceed with carbon block filter replacement CARBON BLOCK PREFILTER REPLACEMENT For m...

Страница 13: ...ials Required One DI SB 10HC Deionization cartridge filter wrench Procedure 1 Remove the filter housing from its cap by rotating it to the left 2 Remove and discard the old cartridge from the housing 3 Thoroughly wash out the housings with hot soapy water to which a few teaspoons of household bleach have been added Rinse well with clean hot water 4 Install the new deionization cartridge Make sure ...

Страница 14: ...filter wrench This may require two people 5 Use a pair of pliers to grasp the membrane stem and pull the membrane from the housing Fig B 6 Remove the black housing O ring Fig B Wash the empty housing with soapy water Rinse thoroughly with hot clean water 7 Insert new membrane into the housing with the double O ring end first Fig C The tube must fit into the recess at the bottom of the membrane hou...

Страница 15: ...ction rate The system must be running to perform this step See Using The Three Probe TDS Meter on page 8 and Membrane Rejection Test on page 11 You may skip step 2 on page 11 as the system has already been running 13 If the membrane rejection rate is 96 or higher turn the system off and reinstall the DI cartridge NOTE Make sure the DI cartridge is in the correct orientation and that the rubber gas...

Страница 16: ...d water and RO product water TDS Conductivity Is Rejection greater than 95 No Replace Membrane Yes Membrane OK Alkalinity Test Kit Measure feed water and RO product water Alkalinity Is Rejection greater than 90 No Replace Membrane Yes Membrane OK Hardness Test Kit Measure feed water and RO product water Hardness Is Rejection greater than 90 No Replace Membrane Yes Membrane OK Caution This test is ...

Страница 17: ... water greatly reduces the chances of membrane fouling 4 Use the optional flush valve kit after each use of the system to extend membrane life STORAGE 1 It is recommended that you store your RO System in a cool dark place when not being used 2 If your system is exposed to sunlight you will grow algae in the housing and it may damage your system 3 Your RO System must be protected from freezing or t...

Страница 18: ...h line pressure 90 psi ii Use a pressure reducing valve 4 High or Unreasonable Readings on TDS Meter a Exhausted deionization cartridge i Replace cartridge b Bad membrane exhausted cartridge ii Replace membrane and deionization cartridge c Faulty monitor probe iii Replace monitor probe d Exhausted batteries iv Replace with 2 357A batteries 5 Pressure gauge does not register anything a Missing flow...

Страница 19: ...nce of tested SpectraSelect RO membrane elements only for one year from date of receipt by the buyer providing that the loss of performance was not caused by fouling neglect or water conditions exceeding the feed water parameters listed in the applicable product manual refer to detailed membrane warranty information SpectraPure will on confirmation of loss of performance during the warranty period...

Страница 20: ...embrane FR 90 RED Flow Restrictors for 90gpd 340 lpd System UPGRADE PARTS Part Number Description MEM SP 0090 90 gpd SpectraSelectPlus 99 Rejection TFC Membrane ACCESSORIES Part Number Description MTR PH80 Hand held pH Meter MTR EC TDS C100 Hand held EC TDS Meter FAU SNP Quick Connect Faucet Adapter TK CL 10 KIT Total Chlorine Test Kit TK CL 10TABS 10 Replacement Tabs for Chlorine Test Kit Visit o...

Отзывы: