MAINTENANCE PROCEDURES (continued)
Post Filter Replacement
Maintenance Regime:
At least once every 12 months or whenever odor or bad taste occurs.
Materials Needed:
Replacement Carbon Post Filter (CF-0.5-10)
Procedure:
1. Turn off feed supply valve and tank shutoff valve.
2. Remove the filter housing from its cap by unscrewing it clockwise as viewed from the top or side.
3. Discard old filter.
4. Thoroughly wash out the housing with hot soapy water to which a few teaspoons of household bleach have been
added, and rinse well with clean hot water.
5. Install the new post filter.
6. Turn on both tank shutoff valve and feed supply valve. (Check for leaks)
Remineralization Cartridge Replacement
Maintenance Regime:
At least once every 12 months or whenever more than 50% of the minerals are exhausted.
Materials Needed:
Replacement Remineralization Cartridge (FA-REMIN-10)
Procedure:
1. Turn off feed supply valve and tank shutoff valve.
2. Remove the filter housing from its cap by unscrewing it clockwise as viewed from the top or side.
3. Discard old cartridge.
4. Thoroughly wash out the housing with hot soapy water to which a few teaspoons of household bleach have been
added, and rinse well with clean hot water.
5. Install the new cartridge.
6. Turn on both tank shutoff valve and feed supply valve. (Check for leaks)
Recharging the Bladder Tank
If the storage capacity of the tank is diminished significantly it is likely that the tank has lost its air charge. Recharging the
bladder tank will restore its capacity.
1. Put the dispenser faucet in the “open” position (lever in up position). Leave the faucet in the open position until the
procedure is completed.
2. Drain as much water as possible from the tank.
3. Hook up an air pump to the “Schrader” (tire) valve on the pressure tank and start pumping air into the tank.
4. Expel all the water from the tank.
5. Continue pumping air into the tank until the pressure reads 6 psi.
6. This completes the procedure.
NOTE: Should this procedure fail to restore the capacity of the tank, it is very likely that the bladder in the tank is
ruptured and the tank needs to be replaced.