TROUBLESHOOTING GUIDE FOR COFFEE LOVERS SYSTEM (continued)
Problem
Cause
Corrective Action
Pressure gauge does not register anything.
a. Plugged prefilters.
i. Replace prefilters
b. Missing flow restrictor.
ii. Put flow restrictor in the yellow brine line.
c. Pressure gauge screwed in too
far.
iii. Unscrew pressure gauge one turn and
retest.
d. Plugged pressure gauge orifice.
iv. Clean orifice with a needle.
e. Defective pressure gauge.
v. Replace it.
Water smells bad.
a. Exhausted post carbon filter.
i. Replace it.
b. Ruptured bladder in storage
tank.
ii. Replace tank.
c. Bacterial contamination of
bladder tank.
iii. Sanitize RO system.
Milky colored water.
a. Air in system.
i. Air in the system is a normal occurrence
with intial startup of the RO system. This
milky appearance will disappear during
normal use within 1-2 weeks. If condition
recurs after filter changes, drain tank 1 to
2 times.
Reject (yellow) line never stops flowing water.
a. Faulty check valve.
i. Replace it.
b. Faulty auto shutoff valve.
ii. Replace it.
Broken faucet handle.
i. Purchase a faucet repair kit.
Troubleshooting Guide Continued on Next Page.