Base Station LED Indicators
Below you will find information about LED indicators on the base station.
Front Cover
The base station front cover has one indicator describing the base station faults and failures. The
indicator is off when the base station is not powered. The LED flashes when the base station ini-
tializes. The indicator is on when the base station is operating.
LED Indicator
Meaning
Steady green
OK and idle.
Slow green flashing
OK and active voice call.
Fast green flashing
Busy (all channels are in use).
Slow red flashing
Missing base station.
Fast red flashing
No sync over air possible, or sync master is not avail-
able, or other error.
Steady red
Reset/shutdown in progress.
Steady red for 5 seconds followed by
fast red flashing
Reset to factory settings.
LAN Port on Face Plate
LED Indicator
Meaning
LINK Indicator - yellow
Link layer software has established connection.
LINK Indicator - green flashing
Activity
Base Station Reset Button
You can restart or reset the base station by pressing the Reset button on the bottom of face plate of
the base station.
The following table contains a description of the different actions that take place when pressing the
Reset button.
Press button
Action
Short press (2 to 5 sec.)
System restarts when button is released.
Long press (5 to 9 sec.) until front LED
flashes red, then release button
Resets the system to factory default settings (original IP
settings (DHCP) and empty user data base) and
restarts the system. Firmware version is not affected.