Max. Cable Length:
4000 ft. using shielded twisted
pair.
Input Impedance:
Switch selectable, 120 ohm
termination or high imped-
ance.
Transient Protection:
Protected by transient voltage
suppressors.
1.5.2
1.5.2
1.5.2
1.5.2
1.5.2
RS-485 Repeater
RS-485 Repeater
RS-485 Repeater
RS-485 Repeater
RS-485 Repeater
Output Signal:
Regenerated RS-485 signal of
applied input data stream.
Max Loading:
32 devices.
1.5.3
1.5.3
1.5.3
1.5.3
1.5.3
User Selectable Options
User Selectable Options
User Selectable Options
User Selectable Options
User Selectable Options
TimeView 400 switches and controls select the following
options: 12- or 24-hour display format, time zone offsets,
display intensity, time set from NetClock Master Clock,
computer, or manually entered, and RS-485 termination.
1.5.4
1.5.4
1.5.4
1.5.4
1.5.4 Power
Power
Power
Power
Power
Power Source:
UL listed AC wall adapter
(supplied).
Input:
115 VAC ±10%, 60 Hz, 22 watts.
Output:
12 VDC, 1 A.
Connector:
Barrel, 5.5 mm O.D., 2.1 mm I.D.,
positive shell, negative center.
Optional Power:
International Power Supply
allows operation from a 90-240
VAC, 47-63 Hz power source.
Specify part number PS00142.
Page 1-5