Model 9289
Spectracom Corporation
NetClock/NTP Network Time Provider Instruction Manual
3-34
From the Interface Set to Defaults screen (Figure 3-38), the user may click the “Restore to
factory defaults” button to set the Interface values (and the Interface values ONLY) to the
factory settings.
3.4.4 Sysplex
Timing
The NetClock may be used as an external time source (ETS) to synchronize an IBM Sysplex
Timer. This is achieved by configuring Serial Port 1 (refer to
Configuring the Interface
) on the
NetClock to the following settings (Figure 3-39):
Baud Rate:
9600
Data Format:
02
Request Char:
User-defined, ‘T’
System Clock:
UTC