Model 9289
Spectracom Corporation
NetClock/NTP Network Time Provider Instruction Manual
3-14
3.3
Issuing the HALT Command before Removing Power
Once power is applied to the NetClock, it should not be removed unless the HALT command is
issued to the unit. This prevents corruption of the NetClock file system.
CAUTION:
Once power is applied to the unit, DO NOT disconnect power
unless the HALT command is first issued to the NetClock. To
be absolutely certain that it is safe to remove power, wait 60
seconds after the HALT command is issued before removing
power.
The HALT command may be issued to the NetClock through the Web UI, through the CLI, or
through SNMP.
3.3.1 Issuing the HALT Command through the Web UI
From the System Reboot/Halt page (Figure 3-15), click the Halt Now button. Wait 30 seconds
after making the HALT request before removing power to the unit. (The system may also be
rebooted from this screen.)
Figure 3-15: System Reboot/Halt Screen (1 of 3)