Spectracom Corporation
8194B, 8195B, 8197B
GPS Ageless Master Oscillator Instruction Manual
4-13
TIME= 14:00:00 DATE= 2004-03-24
0= 00000 1= 00000 2= 00000 3= 00000 4= 00000
5= 00000 6= 00000 7= 00067 8= 03430 9= 00103
10= 00000 11= 00000 12= 00000 Q= 03600
TIME= 15:00:00 DATE= 2004-03-24
0= 00000 1= 00000 2= 00000 3= 00000 4= 00000
5= 00000 6= 00000 7= 00000 8= 02678 9= 00580
10= 00342 11= 00000 12= 00000 Q= 03600
TIME= 15:01:59 DATE= 2004-03-24
0= 00000 1= 00000 2= 00000 3= 00000 4= 00000
5= 00000 6= 00000 7= 00000 8= 00000 9= 00027
10= 00091 11= 00000 12= 00000 Q= 00118
END OF LOG
END OF LOG
4.3.11 Event Output
The Master Oscillator maintains logs on alarm conditions, satellite tracking, oscillator
performance and corrections. Entries made to these logs are automatically output to
the RS-232 port as they are being generated. The
Event Output
command,
EO
, can
enable or disable the automatic output of these entries.
The factory default is
disabled
.
To view the Event Output configuration issue the
EO
command as follows:
Type:
EO<ent>
Response:
EVENT OUTPUT ENABLED
- OR -
EVENT OUTPUT DISABLED
To enable or disable the
Event Output
feature, place the unit in Set Mode and issue
the following command:
Type:
EO ON<ent>
Response:
EVENT OUTPUT ENABLED
- OR -
Type:
EO OFF<ent>
Response:
EVENT OUTPUT DISABLED