3.3.10 DC Power
The DC Power connector provides primary or backup power to the unit
On AC powered units, the DC power connector allows connection of a backup power
source. The backup source powers the oscillator and GPS receiver module whenever
AC power is interrupted. Backup power speeds recovery time when AC power is
restored by eliminating oscillator warm-up and retrace and GPS reacquisition time. The
backup power source must be +24 VDC, non-ground isolated supply of 10 Watts
maximum. When connecting the backup power source, connect a wire jumper from the
negative (-) pin to the ground (G) pin as shown in Figure 3-15. The DC power
connector is shown in Figure 3-16.
Figure 3-15 DC Backup Wiring
DC power options allow operation from alternate power sources. Table 3-10 lists the
various DC power configurations available. Power is 20 Watts for Model 8195B and 60
Watts for Model 8197B.
Power
Option
Nominal
Voltage
Input Range
Fuse
Option 52
± 12 VDC
11.1 - 16.5 VDC
10.0 A
Option 53
± 24 VDC
22.1 - 33.1 VDC
6.25 A Slo-Blo
Option 54
± 48 VDC
44.2 - 66.2 VDC
3.0 A Slo-Blo
Table 3-10 DC Power Configurations
Connect the DC power inputs to the 6-position terminal block as shown in Figure 3-16,
DC Power Connector. The mating connector is included in the ancillary kit. Redundant
power sources may be connected for improved system reliability. Be certain to observe
the polarity markings when connecting power.
1
2
3
4
5
6
BACKUP POWER SOURCE
+24 VDC
−
GROUND
+24 VDC
−
GROUND
+
−
G
+
−
G
PRIMARY
SOURCE
SECONDARY
SOURCE
DC POWER CONNECTOR