ADJUST SHURFLO PRESSURE SWITCH
Shurflo feed pumps are equipped with a high pressure cutout switch (EL-FP-PS). This is the
small black unit on the end of the wet end of the pump head (PL-PMP-SFPH) where the two
red wires connect. If the pressure switch is not properly adjusted the pump may cut out each
time the Clark pump cycles and the feed pressure spikes. When this happens the production
will drop and salinity will increase. The points in the switch will fail quickly if set too low be-
cause of the constant arcing each time the Clark Pump shifts.
On the very center of the switch is a small 5/64” Allen screw. While running the system close
the brine discharge seacock or kink the discharge hose, to block the flow. Watch the pressure
gauge and adjust the pressure switch to shut off at 125 psi. Turn the Allen screw clockwise to
increase the cut off set point.
Pressure Switch
Adjusting Screw
Содержание Ventura 150T MPC
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 7: ...7 Installation ...
Страница 8: ...8 ...
Страница 14: ...14 ...
Страница 28: ...28 ...
Страница 29: ...29 Operation ...
Страница 30: ...30 ...
Страница 38: ...38 ...
Страница 39: ...39 Maintenance Storage and Troubleshooting ...
Страница 40: ...40 ...
Страница 60: ...60 ...
Страница 61: ...61 MPC 5000 Programming and Controls ...
Страница 62: ...62 ...
Страница 72: ...72 ...
Страница 74: ...74 ...
Страница 75: ...75 Exploded Views and Part Numbers ...
Страница 76: ...76 ...
Страница 82: ...82 HP TB VEB B HP TB VB HP TB VEB A HP TB BV HP CB CB7 HP CYL SST HP CYL R HP CYL EC HP CYL CCA Not used ...
Страница 84: ...84 Parts HP CYL 3 4R ...
Страница 85: ...85 PL MTS 3 8X1 2S HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Страница 86: ...86 ...