Wiring
Mount the control box with 4 appropriate fasteners on a vertical surface, above components
containing water, with the wire grommets down, and central to the other system components.
Make sure the cables will reach all of the modules to avoid splices. The main power feed
should come from an appropriately-sized fuse or breaker on the main DC panel. See wire size
and fuse/breaker tables below.
Warning! Do not connect the main power feed until all other connections are made.
Filter Sensor harness
6’ (2M)
Clark Pump harness, Rotoflow meter, and
diversion valve cables 15’ (4.5M). See
next page.
MPC-5000 Display. Mount in
dry, central location. Connects
to control cable.
Main power feed. Install cover
after terminating wires.
Pump power feed: 4’(1.2M). May
be extended as required. Count
additional length in wire sizing.
15’ (4.5M) fresh wa-
ter flush solenoid
cable. Crimp onto to
flush solenoid leads
and heat shrink the
connectors. The
wires have no polari-
ty.
Wire Size Guide for the Ventura 12V:
Protect with 15 Amp Fuse or Circuit Breaker
10 Gauge (5mm
²
) up to 15 feet (4.5M)
8 Gauge (8mm
²
) up to 25 feet (7.5M)
6 Gauge (13mm
²
) up to 35 feet (10.6M)
Wire Size Guide for the Ventura 24V:
Protect with 7 Amp Fuse or Circuit Breaker
10 Gauge (5mm
²
) up to 25 feet (7.6M)
8 Gauge (8mm
²
) up to 35 feet (10.6M)
Distances at left represent the total
ROUND TRIP wire length (DC positive
length plus DC negative length), NOT
the length of the pair of wires togeth-
er. Size cables accordingly.
MPC Control Box
50’ Control Cable (15.2M): Protect
connector while routing through
vessel.
Auto/Manual
toggle switch
Содержание Ventura 150T MPC
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 7: ...7 Installation ...
Страница 8: ...8 ...
Страница 14: ...14 ...
Страница 28: ...28 ...
Страница 29: ...29 Operation ...
Страница 30: ...30 ...
Страница 38: ...38 ...
Страница 39: ...39 Maintenance Storage and Troubleshooting ...
Страница 40: ...40 ...
Страница 60: ...60 ...
Страница 61: ...61 MPC 5000 Programming and Controls ...
Страница 62: ...62 ...
Страница 72: ...72 ...
Страница 74: ...74 ...
Страница 75: ...75 Exploded Views and Part Numbers ...
Страница 76: ...76 ...
Страница 82: ...82 HP TB VEB B HP TB VB HP TB VEB A HP TB BV HP CB CB7 HP CYL SST HP CYL R HP CYL EC HP CYL CCA Not used ...
Страница 84: ...84 Parts HP CYL 3 4R ...
Страница 85: ...85 PL MTS 3 8X1 2S HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...
Страница 86: ...86 ...