Chapter 7. Maintenance, Troubleshooting, and Repairs
69
Replacing the Fuses
The fuses used in the library are 1/4 x 1 1/4 (3AG) or 5x20 mm, 250-volt, 2A slow
fuses. For purchasing information, see
Purchasing Additional Library Accessories
To check or replace the fuses, follow these steps:
1.
Shut down your system and disconnect the AC power cable from the library.
2.
On the back of the library, open the fuse compartment by prying under the
short tab with a small screwdriver. Remove the red fuse holder underneath
(Figure 7-2).
3.
Remove the two fuses and replace them with new fuses.
4.
Insert the fuse holder back into its original location and close the fuse door. The
door may take a little force to shut and will snap when completely closed.
5.
Attach the AC power and Ethernet cables to the library. Turn on your library,
then turn on the computer.
Tab
Figure 7-2
Use a screwdriver to pry open the fuse drawer door.