Part # M017898010000 August 31, 2012
21
ECOTECH EZ
®
Variable Speed Motor/Control
Starting the Pump and Motor/Control
If the
RUN/STOP
button is illuminated, the motor is in the
RUN mode. If the Clock is set and the time of day and day
of week corresponds to a scheduled Program On time,
the motor will automatically ramp up to speed within a
few seconds. Be aware the unit will start in Prime mode
running at full speed for four minutes. After the priming
percent demanded by the operating mode which caused
the pump to start. When the unit is in Prime mode, the
Pressing the
Run Custom Flow
button followed by the
ENTER
button will start the pump in the current Custom Flow
1 setting. To start the pump in the Custom Flow # 2 setting,
press
Run Custom Flow
twice before pressing
ENTER
;
Press the
Run Custom Flow
button three (3) times then
press
ENTER
to Run Custom Flow 3 and Press the
Run
Custom Flow
button Four (4) times then press the
ENTER
button to start the pump in the Run Custom Flow 4 mode.
Stopping the Pump and Motor/Control
Press the RUN/STOP button to stop the pump.
The button will no longer be illuminated.
Running the ECOTECH EZ
®
Motor/Control
per the Program Schedule
The
RUN/STOP
button must be illuminated. The
motor/control will turn on and off automatically at the
programmed start and stop times and it will operate at
format, the current time of day, the current day of the
week, and the current or next Program Schedule that
will run. The Program Schedule may be overridden by
pressing the
Run Custom Flow
button or by pressing
the
Run MAX Flow/Vacuum
button.
The user interface includes two programmable % Flow
time periods for weekdays, Monday through Friday, and
two programmable % Flow steps for weekends, Saturday
and Sunday. These are the times at which the motor/
control will turn on and operate at the programmed
The Default or preprogrammed settings are as follows:
Mon – Fri Flow 1: 7:30AM Time On and 4:00PM Time Off
running at 50% Flow
Mon – Fri Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 70% Flow
Sat –Sun Flow 1: 7:30AM Time On and 4:00PM Time Off
running at 50% Flow
Sat – Sun Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 70% Flow
Custom Flow 1 80% 120 min
Custom Flow 2 55% 240 min
Custom Flow 3 0% 10 min
Custom Flow 4 0% 10 min
You can also schedule the unit with overlapping
program schedules. An example:
Mon – Fri Flow 1: 7:30AM Time On and 8:00PM Time Off
running at 40% Flow
Mon – Fri Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 70% Flow
Sat – Sun Flow 1: 7:30AM Time On and 8:00PM Time Off
running at 45% Flow
Sat – Sun Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 75% Flow
6:00PM. At 6:00PM, the pump will revert back to the 40%
Flow rate until 8:00PM. The same logic also applies to the
above weekend program schedule. This feature could be
used to save energy dollars by running the pump longer
For 24 Hour Operation
Setting the same On and Off times may cause the unit not
to run. An example:
Mon – Fri Flow 1: 6:00 AM Time On and 6:00 AM Time Off
running at XX%.
The unit will turn on and off at the same time and will not
run.
The recommended schedule for 24 hour operation is by
using both Mon – Fri or Sat – Sun Flows. An example:
Mon – Fri Flow 1: 7:00AM Time On and 7:00PM Time Off
running at 40% Flow
Mon – Fri Flow 2: 7:00PM Time On and 7:00AM Time Off
running at 40% Flow
Sat – Sun Flow 1: 7:00AM Time On and 7:00PM Time Off
running at 40% Flow
Sat – Sun Flow 2: 7:00PM Time On and 7:00AM Time Off
running at 40% Flow
22
Part # M017898010000 August 31, 2012
ECOTECH EZ
®
Variable Speed Motor/Control
Priming the Pump
NOTICE
!
Please follow all instructions from the
pump manufacturer’s product manual regarding the pump
priming operation.
For the factory default setting, every time the pump starts
from an Off condition (0% Flow), to ensure the pump is
properly primed, the pump will ramp to full speed (100%
Flow) for four minutes. When this occurs, the MAX icon will
be flashing above the percentage flow indicator. After the
priming time has expired, the pump will operate at the flow
percent that is shown in the display. If it is less than 100%,
the MAX icon will turn off.
The factory default setting can be changed to flows from
30% to 100% (in 5% increments), and time/duration from 0
to 10 minutes (in 1 minute increments), For NO PRIME, 0
minutes should be selected. During priming, the “% Flow”
indicator flashes. See page 18 Section F “Programming for
Pump Priming” for detailed instruction.
Run Max Flow / Vacuum Mode
To enter this mode, press the Run Max Flow / Vacuum
button then press the Enter button. This mode provides an
operation of 100% Max Flow for a duration of 30 minutes.
These settings CANNOT be adjusted. While running in
this mode, the Timer on the user interface will show the
time remaining in the function and the percentage flow will
show 100% Max Flow.
If additional time is needed to clean and vacuum the pool,
or you would like to extend the time in this mode, pressing
the Run Max Flow / Vacuum button again before the timer
reaches zero minutes will reset the timer to 30 minutes.
After the completion of this mode, the unit will resume
running per the program schedule.
The Run Max Flow / Vacuum mode may be stopped at any
time by pressing the
Exit
button.
Manual Speed (Flow) Adjustment
While the pump is operating in any of the programmed
flow modes, (Mon-Fri, Sat-Sun, or Custom Flows), the flow
rate (speed) can be adjusted by pressing of the “Up” or
“Down” arrows. Each press of the “Up” arrow will increase
the % Flow by 5% increments until a maximum of 100% is
reached. Additional pushes of the key will have no further
effect. Each press of the “Down” arrow will decrease the
% Flow by 5 % increments until a minimum of 30% is
reached. Additional pushes of the key will have no further
effect. When the % Flow is changed manually with the
“Up” and “Down” arrow keys the setting is not stored, but
will be maintained until a change in flow is called for by the
program, or the operating mode is cancelled.
Run Custom Flow Mode
This function’s purpose is to allow for regular or special
objectives to be accomplished with a minimal amount
of effort for the user. For example, the default value for
Custom Flow 1 is as follows: programmed. For instructions
on setting additional Custom Flow settings, see page 17.
To Run the Custom Flow operation:
Pressing the Run Custom Flow button followed by
the ENTER button will start the pump in the current
Custom ENTER.
Pressing the Up or Down arrow keys before pressing
ENTER will cycle through the 4 Custom Flow settings.
When running, the Timer on the user interface will show
the time remaining in the program and the percentage flow
will show the programmed percentage of Flow. The timer
will count down the minutes remaining in your function.
The Run Custom Flow mode can be stopped at any time
by pressing the Exit button.
Freeze Protection Feature
NOTICE
!
This feature is for protection of the pump
so water does not freeze inside the pump.
How it works:
The user interface control will monitor the
ambient temperature around the motor/control when the
motor/control is turned off. If the ambient temperature falls
below 40°F, the user interface will run the motor/control
at minimum speed (30% Flow) for 30 minutes followed by
30 minutes of zero flow time. The freeze protection cycle
will not override the time when the Program Schedule
would normally operate the pump.
NOTICE
!
This feature is not for winterizing or
closing a pool in a colder climate.
Winterize
For colder climates where the pool is closed for the winter
season, the electrical power should be shut off to the
motor at the circuit breaker.
NOTICE
!
Follow all pump manufacturer instructions
regarding Winterizing the pump and system.
Содержание Badu EcoMV
Страница 1: ...Installation Operating and Service Manual Badu EcoMV Swimming Pool Pump ...
Страница 9: ......
Страница 38: ...2999999298 Rev 0313 Badu EcoMV ...