Part # M017898010000 August 31, 2012
17
ECOTECH EZ
®
Variable Speed Motor/Control
E) Custom Flow Programming
(NOTE: There can be up to 4 separate Custom Flow settings. All will be programmed as follows)
1. Use (up arrow) and (down arrow) to move through
the four flow settings.
2. Use the (left arrow) and (right arrow) to move through
the time and flow setting process. Use (up arrow) and
(down arrow) to increase or decrease Time and Flow.
Custom Flow 1, 2, 3, 4
% Flow Range: 0 – 100%
Time Range: 10-249 minutes
(Holding down the “Up” or “Down” arrows while setting
the timer, will change the value rapidly)
3. After you have set the Custom Flows 1 through 4, press
Enter to save. You are now returned to the Clock Set
Programming if needed.
4.
Press Enter when you are finished setting the desired
Custom Flow, rate and times of operation. Repeat steps
1-3 to set Custom Flow rates 2-4.
5.
Press Exit if finished programming or press Enter to
continue.
6.
If finished programming, push RUN/STOP button to run
program.
(Note: RUN/STOP button should be lit)