Description
11|2018 EN
13
3.3 Name
plate
IN-VB 40-20-2 F
5.50 kW (5.12 kW) 50 Hz
ID
Q
Eff.
n fix.
PO
Prod.
280402352018V
32.4 m³/h H 34.3 m
69.2% (MEI >= 0,70)
2940 rpm
600137273
27/2015 1190645-020
Seal
Hydr.
Conn.
Ca/SiC/EPDM
PN 10 -20/+100 °C
Easy Access
PN 16 +140 °C
140 °C + PN 16
PN 16/25
SPECK Pumpen Verkaufsgesellschaft GmbH
Hauptstraße 3
91233 Neunkirchen am Sand, Germany
IN-VB 40-20-2 F
Frame 132 (5.12 kW) 50 Hz
ID
Q
Eff.
n fix.
PO
Prod.
280402352018V
32.4 m³/h H 34.3 m
69.2% (MEI >= 0,70)
2940 rpm
600137273
27/2015 1190645-020
Seal
Hydr.
Conn.
Ca/SiC/EPDM
PN 10 -20/+100 °C
Easy Access
PN 16 +140 °C
140 °C + PN 16
PN 16/25
SPECK Pumpen Verkaufsgesellschaft GmbH
Hauptstraße 3
91233 Neunkirchen am Sand, Germany
1
2
3
4
5
6
7
7.1
7.2
8
9
10
11
12
WG56.00.012-P
13
Fig. 3
(1)
Model description
(2)
Flow rate (Q
opt
)
(3)
Minimum efficiency index
(4)
Motor speed
(5)
Serial number
(6)
Production number
(7)
Maximum operational pressure for
mechanical seal at this temperature
(7.1)
Seal code / material
(7.2)
Type of mechanical seal
(8)
Maximum operational pressure for
pump hydraulic at this temperature
(9)
Maximum operational pressure for
connection flange
(10)
Dynamic head in Q
opt
(11)
Maximum power requirement of the
pump
(12)
Motor performance
(13)
Lantern construction size
3.4 Design
The IN-VB and IN-VB-S ranges are multistage centrifugal pumps. The high pressure inline pumps can be
assembled vertically and as an option also horizontally.
The pump’s connection flanges are arranged in a row. This guarantees a simple and compact installation.
A mechanical seal is used as a shaft seal. The following mechanical seals are used:
–
Fixed design (IN-VB/IN-VB-S 2, 4, 6, 10, 15)
• Regular design mechanical seal
• Unbalanced
bellow
seal
•
≤
25 bar
–
Easy access design (IN-VB/IN-VB-S 25, 40, 60, 85)
• Simple
replacement
•
≤
25 bar
• The lantern must not be disassembled during replacement
•
≥
5.5 kW motors must not be disassembled
–
Cartridge design (IN-VB 125)
• Cartridge
seal
• Unbalanced bellow seal for PN 25
• Special balanced design for PN 40
• The lantern must not be disassembled during replacement
•
≥
5.5 kW motors must not be disassembled
All hydraulic parts are made from stainless steel.
Содержание IN-VB
Страница 1: ...DE Originalbetriebsanleitung EN Translation of original operation manual IN VB IN VB S WG56 00 030 P ...
Страница 2: ...Inhaltsverzeichnis DE Originalbetriebsanleitung EN Translation of original operation manual ...
Страница 3: ...DE DE Originalbetriebsanleitung IN VB IN VB S ...
Страница 51: ...EN EN Translation of original operation manual IN VB IN VB S ...
Страница 99: ...11 2018 EN 49 ...