25
Malfunction
Possible cause
Possible solution/
Other information
elimination
Pump running dry
Replace shaft seal
Axial clearance set
See Point 10
incorrectly
Motor Assembly)
Leakage along the
Worn O-ring
Replace O-ring
pump casing
O-ring is not resistant
Replace O-ring with
to the pumped medium
one of a suitable
material
Pump installed under
Depressurise pump
tension
and lines. Support the
connections.
If necessary, fit
compensators
The pump vibrates
Coupling is not
Fit the coupling so that
and is noisy
correctly fitted
it is parallel
Pump not filled
Fill and deaerate the
pump
No or insufficient
Make sure the supply
intake
is sufficient. Check if
the intake line is
blocked
Pump bearings and/or
Replace bearings
motor bearings are
damaged
NPSH value too low
Improve the suction
(cavitation)
conditions
The pump is not
Adapt the system for
working in its operating
operation within the
range
operating range or
select a suitable pump
Pump has internal
Clean pump
deposits or blockages
The pump is standing
Level the surface or
on an uneven surface
connect the pump
securely with the
sub-surface
The pump does not
No electricity at the
Check the power
- Electric circuit
start
terminals
supply
- Main switch
- Fuses
Check the motor
- Motor overload switch
overload switch
- Earth leakage switch
Содержание IN Series
Страница 2: ......
Страница 16: ...14 Ersatzteilzeichnungen und Ersatzteillisten finden Sie ab Seite 29 ...
Страница 30: ...Parts drawing and parts list see from page 29 28 ...
Страница 35: ...IN V S 24 32 45 mit Standard Gleitringdichtung IN V S 24 32 45 with standard mechanical seal 33 ...
Страница 41: ......
Страница 42: ......
Страница 44: ...VG 766 6200 050 2 11 11 D GB BA ...