Overview of possible operating and error messages
If an error occurs, the motor switches off permanently. Exception error:
"Undervoltage". The motor automatically switches back on as soon as the voltage lies
over 209 V for at least 6 seconds.
If an error occurs, the system must be disconnected from the power supply. See
Chapter 2.2 of the original Operating Manual "Non self-priming and self-priming
pumps with/without plastic lanterns (AK version)".
Failure blink rate
red error LED
Possible cause
Solution
1 Failure
of
the
microprocessor
Î
Microprocessor restarts
2 Undervoltage
Î
Power supply
< 180 V AC
Î
Controller automatically
activates when the voltage
is over 209 V for at least
6 seconds
3 Temperature
too high / too low
Î
Temperature too high
> 100°C
Î
Temperature too low
< -20°C
4 Overcurrent
triggering
Î
Current too high
Î
Internal overcurrent
protection switched
5 Overvoltage
Î
Power supply
> 269 V AC
6 Shaft
blocked
Î
Load on the shaft too high
or
Î
motor stopped
7 Self-test
Î
One or more self-tests not
run successfully
8 Motor
error
Î
One or more phases not
connected