The motors are built according to isolation class B or isolation class F, respectively.
Caution: The use of pumps for bath tubs, swimming pools and the
restricted area around them is only permitted if pumps are installed in
accordance with DIN/VDE 0100 part 702. Please consult your licensed
electrician!
The supply circuit has to be protected with a fault current contactor with a
nominal fault current of I
∆
N
≤
30 mA.
The electrical wiring used must have a minimum cross section of 1 mm
2
(HO5RN - F for inside, HO7RN - F for outside).
5.4
Opening of the terminal box cover:
1. It is important to first lever the 4 locking pins (a) loose, then push them up by
hand (approx. 10 mm) until limit stop, see drawing 1.
Caution: Don’t use any force, don’t tear the safety pins out!
2. Lever the 4 cams upwards by putting a screwdriver into the slot (c), see
drawing 2.
3. Lift terminal box cover vertically, see drawing 3.
Closing of the terminal box cover:
1. In order to avoid any damage to the filigree sealing lips (b) put the cover
carefully and
right-angled
onto the casing and push it down.
2. Only when the cover is fitted perfectly to the casing, push the locking pins (a)
until they catch.
D 90.212