25
Characteristics
BADU 46
applicable for water
of 20° C
Total dynamic head H (m)
VKL 21.46.001
Technical data at 50 Hz
BADU
BADU
BADU
BADU
46/5
46/10
46/15
46/22
*
)
*
)
*
)
*
)
In/out, glue socket, d
63 / 50
63 / 50
63 / 50
63 / 50
Recommended inlet/outlet pipe, PVC pipe, d
50 / 50
50 / 50
50 / 50
63 / 50
Power input P
1
(kW)
1~230 V
0,58
0,69
0,97
1,20
Power output P
2
(kW)
1~230 V
0,30
1)
0,45
1)
0,65
1)
0,80
1)
Rated current (A)
1~230 V
2,60
3,20
4,70
5,30
Weight (kg)
6,7
6,7
8,1
10,4
46/5
46/10
46/15
46/22
n=2840min
-1
Förderstrom / Flow rate Q (m /h)
3
2
4
6
8
10
12
14
16
0
5
10
15
20
25
30
Flow rate Q (m
3
/ h)
Type of motor enclosure
IP X4
Thermal class
B
Motor speed approx. (rpm)
2840
Max. water temperature (°C)
60
Max. casing interior pressure (bar)
2,5
Continuous sound intensity level (A)
≤
70
2)
1)
For standard voltage according to IEC 38 und DIN EN
60034 (Eurovoltage).
Suitable for continuous operation at 1~ 220-240 V.
Tolerances ± 5%.
GS-tested pumps according to EN 60335-1.*
)
2)
Measured with a phonometer according to DIN 45635.
Special union included.
*
)
GS approval pending
Содержание BADU 45
Страница 16: ...14 Montage Demontage Z Nr VD21 45 005 ...
Страница 37: ...35 Montage Demontage Z Nr VD21 45 005 Disassembly Assembly ...
Страница 58: ...56 Montage Demontage Z Nr VD21 45 005 Démontage Montage ...
Страница 66: ...64 ...
Страница 68: ...VG 766 2020 055 3 05 07 D GB F BA ...