background image

www.sparrl.com

 

Sparr Electronics Limited 

Page 6

 

 

8.  Configuration

The  device  configuration  files  (config*.txt  and  rtc.txt)  is  used  to  configure  the  CAN  Data  Logger.  The 
configuration  file  can  be  accessed  from  a  PC  when  connected  via  USB  Cable.  While  powering  ON,  the 
device will check for these 2 files if they are present then the device will copy the parameters and delete both 
the files and start working accordingly.

 

7.1. 

config.txt file Configuration:

 

All Configurable parameters will start with “

#

”, followed by “Parameter name”,”=”, “value of the parameter” 

and ends with “

%

”.  

Configurable Parameters 
1) 

CAN Bitrate 

2) 

Model ID 

3) 

File Size 

 

CAN Bitrate:

 Device supports bitrate from 20 Kbps to 500 Kbps. The bit rate can be configured as 

mentioned below. 
#CAN Bitrate=*% 
Where * is the corresponding number of the bit rate selected.  
Example: #CAN Bitrate=6% 
Where 6 is for 500Kbps. 
                        

 

 

 
 
 
 
 
 
 
 

                              

Bit Rate Table 

 

   

Model ID:

  

The Model Id for identifying device, this

 can be configured based on from where the device will be 

collecting the data. It can be up-to 255. 
Model ID is configured as mention below  
#Model ID=***% 
Where *** is the ID number.   
Example: #Model ID=18% 
Where 18 is the Model ID. 

 

File  Size:

 

This  value  is  the  maximum  file  size  in  megabytes,  this  can  be  configuring  from  1MB  to  999MB 

Based on the size configured the logger will record. If a file becomes longer than this, the logger will save the 
file  which  is  currently  recording  and  begin  a  new  log  file  with  the  current  date  and  time  (dd/mm/hh//mm 
format).  

 

 

#File Size=***% 

 

Where *** is the file size in MB 

 

Example: #File Size=10% 

 

Where 10 in the file size (10MB). 

 

Value 

Bit Rate in KB/s 

20 Kbps 

83.3 Kbps 

125 Kbps 

175 Kbps 

225 Kbps 

250 Kbps 

500 Kbps 

Содержание CAN

Страница 1: ......

Страница 2: ...Applications 3 4 Packed Box Contains 4 5 LED Indications 4 6 OBD2 Connector Pin Description 4 7 Modes Of Operation 5 8 Configuration 6 9 Factory Default Values 8 10 Troubleshooting 8 11 Contact and Support 8 Manual Revision Revision Date List of Updates 00 23 09 2016 01 27 07 2017 1 Contact Information ...

Страница 3: ...Load Monitoring CAN device development and test Industrial Automation Bit Rate 20 Kbps to 500 Kbps Connectors OBD2 Male Connector USB micro Connector Storage Up to 16 GB using SD Card Indicators LED Power Red ON when powered from OBD2 Connector Green ON when powered from USB Status Yellow ON When there is no response from CAN Slave device Slow Blink When there is response from CAN Slave device Fas...

Страница 4: ...Color Function Power indication Red The Red LED glows when the device is getting power from the connected CAN Port over OBD2 connector Green The Green LED glows when the device is getting power from the connected PC over USB interface Device status Yellow ON When there is no response from CAN Slave device Blink 800 ms ON 200 ms OFF When there is response from CAN Slave device Blink 40 ms ON 40 ms ...

Страница 5: ...ng mode CAN BUS Connection If the device is powered on through the OBD2 connector it will activate the Data Logging mode When the device enters Data Logging mode the internal memory is reserved allocated for data logging and cannot be accessed through the USB port As the device enters Data Logging mode it will attempt to read the device configuration file located on the memory card the device conf...

Страница 6: ...ned below CAN Bitrate Where is the corresponding number of the bit rate selected Example CAN Bitrate 6 Where 6 is for 500Kbps Bit Rate Table Model ID The Model Id for identifying device this can be configured based on from where the device will be collecting the data It can be up to 255 Model ID is configured as mention below Model ID Where is the ID number Example Model ID 18 Where 18 is the Mode...

Страница 7: ...will start from the set date and time The date and time from RTC is used to create new text file Date setting Date can be set in the dd mm yy day format as mention below DATE dd mm yy day Where dd is Date mm is Month and yy in Year 1 for Monday 2 for Tuesday 3 for Wednesday 4 for Thursday 5 for Friday 6 for Saturday 7 For Sunday Example DATE 19 11 15 2 Where 19 is date 11 is month 15 is year and 2...

Страница 8: ...e device 2 If the Device is not detecting as Drive Check whether USB Cable is connected properly USB Port of the PC is functioning properly Check Green Power LED is ON 3 Data is not logging Check Power Red LED is ON when connected to OBD2 connector Check Status Yellow LED is blinking slowly Check Status Yellow LED if it is blinking fast indicating that memory is full Check config txt file is edite...

Отзывы: