background image

www.sparrl.com

 

Sparr Electronics Limited 

Page 3

 

 

1.  Overview 

  CAN (Controller Area Network) DATA LOGGER is a standalone data collecting unit, which can collect 

and store the data from CAN bus by sending appropriate queries. 

  It has storage capacity up to 16 GB using SD Card. 

  The device supports Communication Rate from 20 Kbps to 500 Kbps 

 

2.  Technical Specifications 

 

 

3.  Applications 

  Automobiles 

  Aerospace 

  Bus Load Monitoring 

  CAN device development and test 

  Industrial Automation. 

 

Bit Rate 

20 Kbps to 500 Kbps 

Connectors 

OBD2 Male Connector & USB micro Connector 

Storage 

Up to 16 GB using SD Card 

Indicators (LED) 

 

Power 

 

Red 

ON when powered from OBD2 Connector 

Green 

ON when powered from USB  

Status 

 

Yellow 

ON 

– When there is no response from CAN Slave device. 

Slow Blink -When there is response from CAN Slave device. 
Fast Blink

– When the Memory is full. 

Power 

 

Input 

12 V DC, 50 mA 

Environmental 

 

Operating 

0 °C to 55 °C 

Storage 

0 °C to 85 °C 

Packaging 

 

Dimensions (LxWxH) 

100 mm(L) x 54 mm(W) x 32 mm (H) 

Weight 

80 g 

Warranty 

12 Months 

Содержание CAN

Страница 1: ......

Страница 2: ...Applications 3 4 Packed Box Contains 4 5 LED Indications 4 6 OBD2 Connector Pin Description 4 7 Modes Of Operation 5 8 Configuration 6 9 Factory Default Values 8 10 Troubleshooting 8 11 Contact and Support 8 Manual Revision Revision Date List of Updates 00 23 09 2016 01 27 07 2017 1 Contact Information ...

Страница 3: ...Load Monitoring CAN device development and test Industrial Automation Bit Rate 20 Kbps to 500 Kbps Connectors OBD2 Male Connector USB micro Connector Storage Up to 16 GB using SD Card Indicators LED Power Red ON when powered from OBD2 Connector Green ON when powered from USB Status Yellow ON When there is no response from CAN Slave device Slow Blink When there is response from CAN Slave device Fas...

Страница 4: ...Color Function Power indication Red The Red LED glows when the device is getting power from the connected CAN Port over OBD2 connector Green The Green LED glows when the device is getting power from the connected PC over USB interface Device status Yellow ON When there is no response from CAN Slave device Blink 800 ms ON 200 ms OFF When there is response from CAN Slave device Blink 40 ms ON 40 ms ...

Страница 5: ...ng mode CAN BUS Connection If the device is powered on through the OBD2 connector it will activate the Data Logging mode When the device enters Data Logging mode the internal memory is reserved allocated for data logging and cannot be accessed through the USB port As the device enters Data Logging mode it will attempt to read the device configuration file located on the memory card the device conf...

Страница 6: ...ned below CAN Bitrate Where is the corresponding number of the bit rate selected Example CAN Bitrate 6 Where 6 is for 500Kbps Bit Rate Table Model ID The Model Id for identifying device this can be configured based on from where the device will be collecting the data It can be up to 255 Model ID is configured as mention below Model ID Where is the ID number Example Model ID 18 Where 18 is the Mode...

Страница 7: ...will start from the set date and time The date and time from RTC is used to create new text file Date setting Date can be set in the dd mm yy day format as mention below DATE dd mm yy day Where dd is Date mm is Month and yy in Year 1 for Monday 2 for Tuesday 3 for Wednesday 4 for Thursday 5 for Friday 6 for Saturday 7 For Sunday Example DATE 19 11 15 2 Where 19 is date 11 is month 15 is year and 2...

Страница 8: ...e device 2 If the Device is not detecting as Drive Check whether USB Cable is connected properly USB Port of the PC is functioning properly Check Green Power LED is ON 3 Data is not logging Check Power Red LED is ON when connected to OBD2 connector Check Status Yellow LED is blinking slowly Check Status Yellow LED if it is blinking fast indicating that memory is full Check config txt file is edite...

Отзывы: