background image

www.sparrl.com

 

Sparr Electronics Limited 

Page 5

 

 

 

 
 
 
 
 
 
 
 
 

  

OBD2 Connector Pin Descriptions 

 

7.  Modes of Operation 

It has two basic modes of operation:  

  Mass storage device mode and 
  Data Logging mode  

The device detects which mode to activate based on the connection. If the device is connected by USB to 
a  PC  during  start-up,  it  will  activate  Mass  storage  device  mode.  Otherwise,  it  will  activate  Data  Logging 
mode. 

 

1) 

Mass storage device mode

 

(USB Connection) 

If the device is powered on by the USB-cable connected to a PC, the device will behave as Mass storage 
device.  In  this  mode  the  internal  memory  will  be  reserved  for  PC  to  access.  The  PC  will  recognize  the 
device as a standard USB memory device Drive such that the device storage can be easily accessed. The 
logged data can now be transferred to the PC without the need of  any  special software. Additionally, the 
device configuration can be accessed and modified (refer section 7). 

 

2) 

Logging mode

 

(CAN BUS Connection) 

If the device is powered on through the OBD2 connector, it will activate the Data Logging mode. When the 
device enters Data Logging mode the internal memory is reserved/allocated for data-logging and cannot be 
accessed through the USB-port. As the device enters Data Logging mode it will attempt to read the device 
configuration file located on the memory-card (the device configuration is described in section 7). If a valid 
configuration file  is found,  the  configuration  is  loaded  into  the  device.  If  no  valid  configuration  is found, a 
previous configuration is written to the memory-card and loaded into the device. The device is now ready to 
communicate with the CAN-bus and log messages according to the loaded device configuration file.

 

Note: 

DO NOT CONNECT USB TO PC WHEN CAN BUS IS CONNETED TO OBD2 FOR DATA LOGGING.

 

 
 
 

PIN 

DESCRIPTION 

PIN 

DESCRIPTION 

Vendor Option 

Vendor Option 

Positive bus line 

10 

Negative bus line 

Vendor Option 

11 

Vendor Option 

Classic Ground 

12 

Vendor Option 

Signal Ground 

13 

Vendor Option 

CAN High 

14 

CAN High 

K Line 

15 

L Line 

Vendor Option 

16 

Battery Power 

Содержание CAN

Страница 1: ......

Страница 2: ...Applications 3 4 Packed Box Contains 4 5 LED Indications 4 6 OBD2 Connector Pin Description 4 7 Modes Of Operation 5 8 Configuration 6 9 Factory Default Values 8 10 Troubleshooting 8 11 Contact and Support 8 Manual Revision Revision Date List of Updates 00 23 09 2016 01 27 07 2017 1 Contact Information ...

Страница 3: ...Load Monitoring CAN device development and test Industrial Automation Bit Rate 20 Kbps to 500 Kbps Connectors OBD2 Male Connector USB micro Connector Storage Up to 16 GB using SD Card Indicators LED Power Red ON when powered from OBD2 Connector Green ON when powered from USB Status Yellow ON When there is no response from CAN Slave device Slow Blink When there is response from CAN Slave device Fas...

Страница 4: ...Color Function Power indication Red The Red LED glows when the device is getting power from the connected CAN Port over OBD2 connector Green The Green LED glows when the device is getting power from the connected PC over USB interface Device status Yellow ON When there is no response from CAN Slave device Blink 800 ms ON 200 ms OFF When there is response from CAN Slave device Blink 40 ms ON 40 ms ...

Страница 5: ...ng mode CAN BUS Connection If the device is powered on through the OBD2 connector it will activate the Data Logging mode When the device enters Data Logging mode the internal memory is reserved allocated for data logging and cannot be accessed through the USB port As the device enters Data Logging mode it will attempt to read the device configuration file located on the memory card the device conf...

Страница 6: ...ned below CAN Bitrate Where is the corresponding number of the bit rate selected Example CAN Bitrate 6 Where 6 is for 500Kbps Bit Rate Table Model ID The Model Id for identifying device this can be configured based on from where the device will be collecting the data It can be up to 255 Model ID is configured as mention below Model ID Where is the ID number Example Model ID 18 Where 18 is the Mode...

Страница 7: ...will start from the set date and time The date and time from RTC is used to create new text file Date setting Date can be set in the dd mm yy day format as mention below DATE dd mm yy day Where dd is Date mm is Month and yy in Year 1 for Monday 2 for Tuesday 3 for Wednesday 4 for Thursday 5 for Friday 6 for Saturday 7 For Sunday Example DATE 19 11 15 2 Where 19 is date 11 is month 15 is year and 2...

Страница 8: ...e device 2 If the Device is not detecting as Drive Check whether USB Cable is connected properly USB Port of the PC is functioning properly Check Green Power LED is ON 3 Data is not logging Check Power Red LED is ON when connected to OBD2 connector Check Status Yellow LED is blinking slowly Check Status Yellow LED if it is blinking fast indicating that memory is full Check config txt file is edite...