manualshive.com logo in svg
background image

 

 

 

 
 
 
 

 

 
 
 
 
 
 
 

blue PiraT Mini 

User Guide 

Version 3.4.1 / 12/14/2018 

 
 
 
 
 
 

 

 
 
 

Содержание Telemotive blue PiraT Mini

Страница 1: ...blue PiraT Mini User Guide Version 3 4 1 12 14 2018 ...

Страница 2: ...nd ETH 4 19 7 7 Multifunction connector 44 pol SUB D HD 19 7 8 Multifunction connector 15 pol SUB D 19 7 9 MOST150 interface 21 7 10 MOST150 cPhy interface Simplex or Duplex 21 7 11 Default network settings 21 7 11 1 Resetting the network settings 21 8 Starting the blue PiraT Mini 22 8 1 Download and installation of the Telemotive System Client 23 9 Adapter cables 25 9 1 blue PiraT Mini cable set ...

Страница 3: ...version of recorded traces 39 12 1 Conversion format overview 39 13 Service and safety instructions 40 14 Data sheet 42 14 1 Data sheet blue PiraT 8 CAN 4 CAN FD 8 LIN 20 LIN 42 14 2 Data sheet blue PiraT MOST150 MOST150 cPhy FlexRay 45 15 Pin assignments and harnesses 48 15 1 Pin assignment 44 pol SUB D blue PiraT Mini 8 CAN 48 15 2 Pin assignment 44 pol SUB D blue PiraT Mini 4 CAN FD 50 15 3 Pin...

Страница 4: ...is not entitled to transmit or to transfer the software or its rights from this license agreement 6 Licensor is not liable to licensee for any damages including compensatory special incidental exemplary punitive or consequential damages connected with or resulting from this license agreement or licensee s use of this software 7 Licensee agrees to defend and indemnify licensor and hold licensor har...

Страница 5: ...ite 5 von 60 blue_PiraT_Mini_UserManual_V3 4 1 doc 2 PRODUCT LIABILITY The General Terms and Conditions of Sale and Delivery of MAGNA Telemotive GmbH can be found on our website at General_Terms_and_Conditions_of_Sale_and_Delivery_Telemotive_AG pdf ...

Страница 6: ...the logged trace data is described in the user guide of the Telemotive System Client This document refers to firmware version 03 04 01 and the Telemotive System Client from version 3 4 1 Some features depending on model and feature license or may not be available in older versions Software updates and user guides for other optional licensed enhancements are available in the Telemotive ServiceCente...

Страница 7: ...tems and control units is monitored and relevant data can be recorded very precisely with the data logger of Telemotive AG The collected data are stored to the logger and can be downloaded via Ethernet to a PC The blue PiraT Mini is smallest data logger in the world with an outstanding functional scope It offers a wide range of interfaces stable temperature behavior very low energy consumption fou...

Страница 8: ...erManual pdf User manual for blue PiraT Mini https www telemotive de 4 uploads media blue_PiraT_Mini_UserManual pdf User manual for Remote Control Touch https sc telemotive de 4 uploads media RCTouch_UserGuide pdf User manual for blue PiraT Remote https sc telemotive de 4 uploads media blue_PiraT_Remote_UserGuide pdf For having an easy access if necessary the most important manuals are linked in t...

Страница 9: ...e Care is required to update the FW to its current state Our sales department offers different versions to meet all customer requirements Please contact our sales department for an offer tailored to your needs See contact on the last page Affected products blue PiraT Mini blue PiraT2 5E blue PiraT2 blue PiraT Remote Remote Control Touch Note Enhancements are only possible in current firmware relea...

Страница 10: ...net For the down load and the conversion of the logging data the Telemotive System Client is available For the available conversion options to various trace file formats please have a look at chapter Conversion format overview The blue PiraT Mini is available with different features see chapter Additional features by optional licenses The blue PiraT Mini is designed to create minimum interference ...

Страница 11: ...ble for the blue PiraT Mini data logger various adapter cables the Remote Control Voice which additionally allows recording of voice note licenses which enhance the functionality of the blue PiraT Mini mounting bracket Please contact Telemotive sales for more information about these accessories Manuals are available from the Telemotive ServiceCenter ...

Страница 12: ...unctionality for Ethernet XCP on Ethernet and the CAN bus XCP on CAN are available MOST150 Streaming logging MOST150 synchronous isochronous data MLBevo The license Connected Gateway MLBevo enables the recording of data of the ATOP control unit MLBevo via USB to the Telemotive data logger and convert these data with the Telemotive System Client from FW 02 03 01 Telemotive Download Terminal Telemot...

Страница 13: ...rsions to offer a wide range of connec tivity in relation to the available interfaces So an optimal utilization is ensured depending on the existing bus systems The table below shows which busses will be supported from the different models of blue PiraT Mini Please consider that the using of Broad R Reach or TSL reduces the quantity of available Gbit Ethernet interfaces Table 6 1 Versions of the b...

Страница 14: ...raT Mini 6 3 Rear side On the rear side are two more 1 Gbit Ethernet ports ETH 3 and ETH 4 and the 44 pol SUB D HD multifunctional main connector for power supply and some of the Interfaces Figure 6 2 Rear side of the blue PiraT Mini 8 CAN 4 CAN FD 8 LIN FlexRay 20 LIN On the rear side of blue PiraT Mini MOST the multifunctional main connector for power supply and some of the interfaces are realiz...

Страница 15: ...Beside the possibility to reset the network settings the blue PiraT Mini offers the possibility to reset the device to factory respectively delivery status if the logger is in error state and there s no chance to connect to the logger any more even after a network reset Warning Due to the reset to factory settings all data and licenses on the logger will be deleted Needed licenses have to be insta...

Страница 16: ...or a short time 7 2 2 STATE LED red State Meaning Off No bug normal operational status On Device is in error state If the device is still reachable by the client the error and some hints to solve this issue can be found in the bug reporter blinking Overload of the data logger maybe loss of data Information about lost data can be found in the bug reporter blinking When using external storage The ex...

Страница 17: ...allel recording File system FAT32 NTFS or ext4 USB Version 2 0 partly USB 3 0 memory is also supported You could connect USB flash drives and external hard drive up to a maximal supply current of 500 mA External power supplies must not be connected to the hard disk If the USB memory is pulled in the operational state the following problems exists The logger is in an undefined state and will not re...

Страница 18: ...HC Transcend Ultimate Speed 16 GB SDXC Kingston SD10VG2 32 GB SDHC Kingston SDA3 16 GB SDHC Intenso 3431490 Professional 64 GB SDXC Intenso 3431470 32 GB SDHC Hama Class 10 45 Mbps 64 GB SDXC Hama Class 10 45 Mbps 16 GB SDHC Extrememory HyPerformance Class 10 32 GB SDHC Extrememory Performance Class 6 16 GB SDHC SanDisk Extreme 32 GB SDHC Table 7 4 Compatible SD cards Attention The format of cards...

Страница 19: ...connect ETH 3 and ETH 4 directly to each other 7 7 Multifunction connector 44 pol SUB D HD At blue PiraT Mini 8 CAN 4 CAN FD 8 LIN 20 LIN FlexRay this connector has these func tions depending on the logger model Power supply KL 30 and KL 31 Clamp 15 KL 15 High Speed CAN HS CAN Low Speed CAN Remote Control LS CAN CAN FD CAN FD LIN LIN FlexRay FR x Ch A Ch B Serial RS232 Analog Digital IN ANA IN ANA...

Страница 20: ...blue PiraT Mini User Guide Datum 14 12 2018 Seite 20 von 60 blue_PiraT_Mini_UserManual_V3 4 1 doc Digital OUT DIG OUT The pinning is described in chapter 15 Pin assignments and harnesses ...

Страница 21: ...he MOST150 cPhy connector is he newer version of MOST150 with electrical instead of opti cal data transfer 7 11 Default network settings Important The loggers default setting is Automatic DHCP configuration for TSL with IP 192 168 0 233 and has to be connected by an Ethernet cable to your computer system You can download the Telemotive System Client by typing this IP address into your web browser ...

Страница 22: ...nfigured as Automatic DHCP configuration for TSL with IP 192 168 0 233 Figure 8 1 Power connection When the power supply is switched on the logger will start automatically when you plug in the power supply Is the blue PiraT Mini in standby mode please press the ON Trigger button to start the de vice To switch off the blue PiraT Mini please press the ON Trigger button for about 5 seconds till the g...

Страница 23: ... to Obtain IP address automati cally Click Download to download the Telemotive System Client 64 Bit version directly from the logger The 32 Bit version is available in our service center Follow these steps depending on your browser Browser Proceeding Internet Explorer Click Save to save the file locally on your system Click Accomplish Mozilla Firefox Click Save file to locally save the file on you...

Страница 24: ...ing operations are described extensively detailed description of the Telemotive System Client configuration of the data logger download of the recorded data conversion of the recorded data Firmware License update creating a bug report You can open the manual directly via this link Manual for the Telemotive System Client https sc telemotive de 4 uploads media TelemotiveSystemClient_UserManual pdf F...

Страница 25: ... multi function connectors and split up its lines to separate connectors 9 1 blue PiraT Mini cable set 8 CAN Figure 9 1 blue PiraT Mini cable set 8 CAN Attention The cable sets of blue PiraT Mini 8 CAN and blue PiraT Mini 4 CAN FD have differ ences in the polarity of the BroadR Reach connectors at the 44 pol SUB D connector Please refer to the pinning in the appendix 9 2 blue PiraT Mini cable set ...

Страница 26: ...PiraT Mini cable set 8 LIN Figure 9 3 blue PiraT Mini cable set 9 LIN 9 4 blue PiraT Mini cable set 20 LIN Figure 9 4 blue PiraT Mini cable set 20 LIN Attention The blue PiraT Mini 20 LIN has one special LIN interface LIN 20 which needs a separate power supply This power connectors are part of the cable set ...

Страница 27: ...m 14 12 2018 Seite 27 von 60 blue_PiraT_Mini_UserManual_V3 4 1 doc 9 5 blue PiraT Mini cable set MOST150 Figure 9 5 blue PiraT Mini cable set MOST150 9 6 blue PiraT Mini cable set FlexRay Figure 9 6 blue PiraT Mini cable set FlexRay ...

Страница 28: ...cial devices that support those protocols If the application is listening to a bidirectional serial communication of two devices two serial ports of the blue PiraT Mini have to be used The Tx lines must not be connected in this case Device 1 Device 2 blue PiraT Rx Tx Rx Tx RS232 1 Rx RS232 1 Tx RS232 2 Rx RS232 2 Tx Figure 9 7 Listening to a bidirectional serial communication 9 8 Adapter cable for...

Страница 29: ...lly complex triggers are making it possible to define a message that triggers a mark er In all cases marker triggers are debounced When downloading the data the client displays all markers in a data overview In this data overview the client can be configured to transfer the data close to selected markers 10 1 1 Setting marker with an extern push button It is also possible to use the digital inputs...

Страница 30: ...log IN are combined to one wire at blue PiraT Mini Please connect the ground for Analog IN when you use an external push button 10 2 Time stamp Usually the recorded messages will get a time stamp at the end of each received message The time stamp is included on most interfaces at the end of the message Only for the serial inter face RS232 the start of the transfer will be used as timestamp Trace D...

Страница 31: ...ite 31 von 60 blue_PiraT_Mini_UserManual_V3 4 1 doc 10 3 Standby mode The table below shows which busses or signals are monitored for keeping the logger alive and which busses or signals are able to wake up the logger Table 10 2 Standby mode Index ...

Страница 32: ...FD interfaces It is not possible to change a CAN interface Each type is using different transceivers The electrical behavior of the Low Speed and the High Speed CAN is different hence the Low Speed CAN port of the blue PiraT Mini must not be connected to a High Speed CAN bus and vice versa Both operating modes use differential signals CANH CANL For the correct data recording all nodes of the bus m...

Страница 33: ... 4 Sending CAN messages If the blue PiraT Mini sends a CAN message it is shown twice in the trace The first message indicates the transmit request of the data logger and the second message indicates the actual transmission of the message In the CANoe file format these messages are indicated as TxRq and Tx respectively The transmit request messages are not included in file format that don t support...

Страница 34: ...sage receives a time stamp which marks the end of the message If the data log ger receives LIN data without a valid header it creates blocks containing the erroneous data The maximum block size is 10 bytes A block is also concluded after a timeout which is three times the transmission time of a LIN character 11 2 2 LIN transceiver The blue PiraT Mini uses the LIN transceiver TJA1021 by NXP former ...

Страница 35: ...e threshold voltages for data reception are the usual RS232 defined values A logical 1 is recognized for input voltages smaller 0 Volts a logical 0 for input voltages higher than 3 Volts 11 4 FlexRay The blue PiraT Mini is able to record FlexRay bus data according to the FlexRay specification 2 1A The data logger records all valid and invalid static and dynamic frames of the two FlexRay channels i...

Страница 36: ...he data logger to the PC and for the TSL Telemotive System Link connection BroadR Reach is an Ethernet based standard which allows multiple components of the electri cal system of a vehicle to get access to information by using unshielded twisted pair wires sim ultaneously The blue PiraT Mini CAN 4 CAN FD allows to disable the rear Ethernet ports ETH 3 and ETH 4 and activate the connectors BRR 1 a...

Страница 37: ...onnection for logging data again 11 7 1 5 TCPServer The blue PiraT Mini can be configured as a TCP server by setting up an IP address and port number There is an adjustable timeout The connection will be terminated if no data arrives This ap pears as a message in the trace file There is no configurable debug level The blue PiraT Mini as a TCP server accepts TCP data packets TCP multicast and TCP b...

Страница 38: ...esis is implemented Before log ging MEP and MDP messages again the ring buffer data has to be fully stored on the hard disk Before starting the logging of the MEP and MDP messages again the system sends a Lost Message This message contains information about how many messages of which type were rejected 11 9 ECL Currently the ECL Electrical Control Line is only supported in conjunction with MOST150...

Страница 39: ...be converted to an Extended TMT format xtmt The client provides the possibility to convert the internal format in other formats to make the data readable or to prepare them for available analyzing tools More information about the file formats and a detailed manual for conversion can be found at the Telemotive System Client User Guide 12 1 Conversion format overview The table below shows which data...

Страница 40: ...t see chapter Data sheet All tests to determine the valid operational temperature are performed under laboratory condi tions In real operation deviating temperatures can occur Internal cut off mechanisms exist that prevent impermissible heating of the device s components A sufficient ventilation is to be taken into consideration The unit and other components shall not be stacked atop each other pr...

Страница 41: ...on to positive electrical potential Klemme 30 Clamp 30 for one related pair and the nega tive one Klemme 31 Clamp 31 for the other matching pair Warning A short circuit directly at the connector between clamb 30 and clamb 31 leads to the de struction of the device The cable sets temperature range is restricted to 20 C to 70 C due to the banana plugs Mounting In laboratory setups and automobiles th...

Страница 42: ...ca 1 7s 21s Standby Mode Configurable time without bus load Configurable time without bus load Configurable time without bus load Configurable time without bus load Wake HS CAN LS CAN LIN Serial KL 15 ON Trigger button HS CAN LS CAN LIN Serial KL 15 ON Trigger button HS CAN LS CAN LIN Serial KL 15 ON Trigger button HS CAN LS CAN LIN Serial KL 15 ON Trigger button Data loss by power loss If the dev...

Страница 43: ...00 19200 38400 57600 115200 230400 Baud 1200 2400 4800 9600 19200 38400 57600 115200 230400 Baud 1200 2400 4800 9600 19200 38400 57600 115200 230400 Baud Data bits 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 Stop bits 1 1 5 2 1 1 5 2 1 1 5 2 1 1 5 2 Parity None odd even None odd even None odd even None odd even LIN recording bPMini 8 CAN bPMini 4 CAN FD bPMini 8 LIN bPMini 20 LIN Channel 2 2 8 20 Baud rate 12...

Страница 44: ...hysically identical with analog input 2 physically identical with analog input Switching threshold 7 V 0 2 V 7 V 0 2 V 7 V 0 2 V 7 V 0 2 V Sampling interval 1 ms to 100 s 1 ms to 100 s 1 ms to 100 s 1 ms to 100 s Digitale output bPMini 8 CAN bPMini 4 CAN FD bPMini 8 LIN bPMini 20 LIN Channel 2 2 2 2 Output voltage Ubat Ubat Ubat Ubat Output current Up to 1 0 A continu ous load Up to 1 0 A continu ...

Страница 45: ... BroadR Reach AutoNeg off ca 1 7s 21s ca 1 7s 21s ca 1 7s 21s Standby Mode Configurable time without bus load Configurable time without bus load Configurable time with out bus load Wake HS CAN LS CAN LIN Serial KL 15 ON Trigger button MOST HS CAN LS CAN LIN Serial KL 15 ON Trigger button MOST HS CAN LS CAN LIN Serial KL 15 ON Trigger button FlexRay Data loss by power loss If the device is switched...

Страница 46: ...PMini MOST bPMini MOST150 cPhy bPMini FlexRay Channel 1 High Speed 1 High Low Speed mixed 1 High Speed 1 High Low Speed mixed 4 High Speed 1 Low Speed Baud rate Up to 1000000 Baud at HS CAN up to 125000 Baud at LS CAN Up to 1000000 Baud at HS CAN up to 125000 Baud at LS CAN Up to 1000000 Baud at HS CAN up to 125000 Baud at LS CAN Transceiver TJA1041A TJA1055T TJA1041A TJA1055T TJA1041A TJA1055T Fi...

Страница 47: ...ternal Range of measurement Channel 1 0V to 30V Channel 2 3 0V to 20V Channel 1 0V to 30V Channel 2 3 0V to 20V Channel 1 0V to 30V Channel 2 3 0V to 20V Resolution 8 mV 8 mV 8 mV Accuracy 3 0 16V 4 16 20 32V 3 0 16V 4 16 20 32V 3 0 16V 4 16 20 32V Sampling interval 1 ms to 100 s 1 ms to 100 s 1 ms to 100 s Digital input bPMini MOST bPMini MOST150 cPhy bPMini FlexRay Channel 2 physically identical...

Страница 48: ... male 7 9 HSCAN_L_4 High Speed CAN 05 LOW DSUB 9 male 2 10 HSCAN_H_4 High Speed CAN 05 HIGH DSUB 9 male 7 11 HSCAN_L_5 High Speed CAN 06 LOW DSUB 9 male 2 12 HSCAN_H_5 High Speed CAN 06 HIGH DSUB 9 male 7 13 LSCAN_L_0 Low Speed CAN LOW DSUB 9 male 2 14 LSCAN_H_0 Low Speed CAN HIGH DSUB 9 male 7 15 KL 31 power supply banana plug black 1 16 KL 31 power supply combined with 15 1 17 HSCAN_L_6 High Spe...

Страница 49: ... Broad R Reach 1 MCD 5 white 2 38 BRR 0 Broad R Reach 1 MCD 5 green 3 39 BRR 1 Broad R Reach 2 MCD 5 white 2 40 BRR 1 Broad R Reach 2 MCD 5 green 3 41 V24 RX 4 Serial RS232 5 RX DSUB 9 male 2 42 V24 TX 4 Serial RS232 5 TX DSUB 9 male 3 43 DIG OUT 2 Digital OUT 2 banana jack green 1 44 DIG OUT 1 Digital OUT 1 banana jack green 1 Table 15 1 Pin assignment 44 pol SUB D blue PiraT Mini 8 CAN The Broad...

Страница 50: ...nected 19 Serial RS232 1 RX DSUB 9 male 2 20 Serial RS232 1 TX DSUB 9 male 3 21 Serial l RS232 2 RX DSUB 9 male 2 22 Serial RS232 2 TX DSUB 9 male 3 23 Serial RS232 3 RX DSUB 9 male 2 24 Serial RS232 3 TX DSUB 9 male 3 25 Serial RS232 4 RX DSUB 9 male 2 26 Serial RS232 4 TX DSUB 9 male 3 27 not connected 28 not connected 29 power supply KL 30 combined with 30 1 30 power supply KL 30 Fuse 5 A banan...

Страница 51: ...ot connected 19 Serial RS232 1 RX DSUB 9 male 2 20 Serial RS232 1 TX DSUB 9 male 3 21 Serial RS232 2 RX DSUB 9 male 2 22 Serial RS232 2 TX DSUB 9 male 3 23 Serial RS232 3 RX DSUB 9 male 2 24 Serial RS232 3 TX DSUB 9 male 3 25 Serial RS232 4 RX DSUB 9 male 2 26 Serial RS232 4 TX DSUB 9 male 3 27 not connected 28 not connected 29 power supply KL 30 combined with 30 1 30 power supply KL 30 Fuse 5 A b...

Страница 52: ...LIN 11 DSUB 9 male 7 19 Serial RS232 1 RX DSUB 9 male 2 20 Serial RS232 1 TX DSUB 9 male 3 21 LIN 12 DSUB 9 male 7 22 LIN 13 DSUB 9 male 7 23 LIN 14 DSUB 9 male 7 24 LIN 15 DSUB 9 male 7 25 LIN 16 DSUB 9 male 7 26 LIN 17 DSUB 9 male 7 27 LIN 18 DSUB 9 male 7 28 LIN 19 DSUB 9 male 7 29 power supply KL 30 combined with 29 1 30 power supply KL 30 Fuse 5 A banana plug red 1 31 wake up from KL15 banana...

Страница 53: ...AN 02 HIGH DSUB 9 male 7 5 power supply KL 31 banana plug black 1 6 power supply KL 31 combined with 5 1 7 Serial RS232 1 RX DSUB 9 male 2 8 Serial RS232 2 RX DSUB 9 male 2 9 power supply KL 30 combined with 10 1 10 power supply KL 30 Fuse 5 A banana plug red 1 11 RS232 3 RX DSUB 9 male 2 12 RS232 4 RX ECL DSUB 9 male 2 13 Analog Dig Interface 2 IN banana plug yellow 1 14 Analog Dig Interface 3 IN...

Страница 54: ... 18 FlexRay Channel 3a DSUB 9 male 2 19 Serial RS232 1 RX DSUB 9 male 2 20 Serial RS232 1 TX DSUB 9 male 3 21 Serial RS232 2 RX DSUB 9 male 2 22 Serial RS232 2 TX DSUB 9 male 3 23 Serial RS232 3 RX DSUB 9 male 2 24 Serial RS232 3 TX DSUB 9 male 3 25 Serial RS232 4 RX DSUB 9 male 2 26 Serial RS232 4 TX DSUB 9 male 3 27 FlexRay Channel 3b DSUB 9 male 7 28 FlexRay Channel 3b DSUB 9 male 2 29 power su...

Страница 55: ...15 8 MOST150 cPhy Connector electrical Table 15 8 MOST150 cPhy Connector electrical Table 15 9 Pinning MOST150 cPhy Connector electrical Figure 15 3 MOST150 cPhy Connector electrical Simplex Duplex Name Typ Hersteller Nr Hersteller MOST25 MOST150 Fiber Optic Connector TYCO 1355426 TYCO Name Typ Hersteller Nr Hersteller MOST150 cPhy FAKRA HF 59S20X 40ML5 Y Rosenberger 59S20X 40ML5 Y Signal 1 RX TX ...

Страница 56: ...ller Area Network CCP CAN Calibration Protocol CF Compact Flash CRO Command Receive Object DAQ Data Acquisition DTO Data Transmission Object ECL Electrical Control Line ECU Electronic Control Unit FIBEX FIeld Bus Exchange Format FW Firmware GMT Greenwich Mean Time INCA INtegrated Calibration and Application Tool LAN Local Area Network Netzwerk LIN Local Interconnect Network MAC Media Access Contro...

Страница 57: ...ol SHA Secure Hash SSL Secure Sockets Layer TCP IP Transmission Control Protocol Internet Protocol TLS Transport Layer Security TMP Telemotive Packetformat TSL Telemotive System Link UDP User Datagram Protocol USB Universal Serial Bus UTC Universal Time Coordinated Wi Fi Wireless Fidelity WLAN Wireless Local Area Network XCP Universal Measurement and Calibration Protocol Table 16 1 Abbreviations I...

Страница 58: ...s to the manuals 24 Figure 9 1 blue PiraT Mini cable set 8 CAN 25 Figure 9 2 blue PiraT Mini cable set 4 CAN FD 25 Figure 9 3 blue PiraT Mini cable set 9 LIN 26 Figure 9 4 blue PiraT Mini cable set 20 LIN 26 Figure 9 5 blue PiraT Mini cable set MOST150 27 Figure 9 6 blue PiraT Mini cable set FlexRay 27 Figure 9 7 Listening to a bidirectional serial communication 28 Figure 9 8 Adapter cable for Rem...

Страница 59: ... 12 1 Conversion options overview 39 Table 14 1 Datasheet blue PiraT Mini 8 CAN 4 CAN FD 8 LIN 20 LIN 44 Table 14 2 Datasheet blue PiraT Mini MOST150 MOST150 cPhy FlexRay 47 Table 15 1 Pin assignment 44 pol SUB D blue PiraT Mini 8 CAN 49 Table 15 2 Pin assignment 44 pol SUB D blue PiraT Mini 4 CAN FD 50 Table 15 3 Pin assignment 44 pol SUB D blue PiraT Mini 8 LIN 51 Table 15 4 Pin assignment 44 po...

Страница 60: ... 0 Fax 49 89 357186 520 E Mail TMO info magna com Web www telemotive de Sales Tel 49 89 357186 550 Fax 49 89 357186 520 E Mail TMO Sales magna com Support Tel 49 89 357186 518 E Mail TMO productsupport magna com ServiceCenter https sc telemotive de bluepirat by MAGNA Telemotive GmbH 2018 Subject to errors and to technical changes as part of product improvement ...

Отзывы: