Refrigerant Requirements
Spaceman requires that only the specified
refrigerant be used in your machine.
Alternative refrigerants may cause damage to
the cooling system and/or prevent the machine
from operating at optimal performance.
If you require an alternative refrigerant, please
call Spaceman Technical Support for a list of
compatible alternatives for your compressor.
Machine placement requirements
•
Place on a flat, level, and solid surface fitted to the
machine dimensions.
•
Ensure a minimum 152mm (6'') clearance on the
exhaust side (Side or Back); units with
Airchute
installed do not need to meet this clearance
requirements.
•
Completely clear area of dust, grease, and airborne
particles.
•
Place away from hot equipment such as stoves, frying
baskets, ovens, etc.
CAUTION: The machine must be placed on a level
surface away from walls and other objects.
Failure
to comply will damage the machine and
refrigeration components and will void all
warranties.
CAUTION: The machine is designed to operate in
normal ambient temperatures of 16
o
C to 24
o
C (60
o
F
to 75
o
F).
Operating in higher ambient temperatures
will result in degraded performance.
Power Connection
L
N
G
L1
L2
L3
G
1.
Connect all wires to Circuit Breaker (including neutral &
ground bus terminals) or Local Plug according to supply
voltage and wire codes on machine power cable.
2.
Verify Incoming Supply Cable is wired the same way on
Circuit Breaker or Wall Receptacle before switching on
or plugging in the machine.
Must Check Motor Rotation!
Switch
on
power
and
verify
that
motor
turns clockwise as
per Red Arrow on motor pulley. If not, switch any two line
wires on Circuit Breaker or Plug and verify again.
IMPORTANT:
Machine will
NOT
work properly and
WILL be damaged if motor
turns in wrong direction.
Attention 3 Phase Machines
Min
152mm
(6'')
4
Installation Requirements
The image displayed is for illustration purpose only and may
differ from the actual product.
220V
50HZ
1PH
L
N
G
220V
60HZ
1PH
L1
L2
G
110V
60HZ
1PH
220V
60HZ
3PH
U
V
W
N
G
380V
50HZ
3PH