8.1.5
Failure to ignite will result in the ignition controller going to "Lockout" condition.
8.1.6
If 'Lockout' occurs, switch off the electrical supply to the appliance, wait for 10 seconds before switching on the
electrical supply to the appliance to repeat the ignition sequence.
8.1.7
If the appliance fails to ignite after a second sequence, switch off the electricity supply to the appliance and call
the service engineer.
8.1.8
If gas failure occurs after successful ignition, the appliance will attempt one re-ignition before going to
"Lockout" conditions.
8.1.9
To shut down the appliance for short periods of time, switch off the electrical supply to the appliance.
8.1.10 To shut down the appliance for longer periods of time switch off the electrical supply to the appliance and turn
off the gas supply at the gas isolation valve.
8.2
Standing Pilot Ignition Models
8.2.1
Turn on the gas supply to the appliance.
8.2.2
If the appliance has a thermostat fitted, ensure that it is set to the lowest temperature setting. Press slightly and
turn the control knob of the millivolt valve clockwise to the OFF position and wait 5minutes thus allowing any
gases to escape, which may have accumulated in the combustion chamber.
8.2.3
Press slightly and turn the control knob counter clockwise to the PILOT position, depress the control knob and
ignite the pilot by passing a lighted tapes through the hole in the side of the pilot housing (venting of air may
take place prior to flow of pilot gases). Once the pilot flame is established hold the knob depressed for
approximately 60 seconds.
8.2.4
Release the knob. If the pilot flame should become extinguished, turn the control knob to OFF position and
repeat steps 8.2.3 and 8.2.4.
Note: this will allow reset of INTERLOCK for correct ignition of the pilot.
8.2.5
Press and turn the control knob counter clockwise to the ON position.
8.2.6
Turn the appliance thermostat to the desired temperature setting, or operate the ON/OFF switch (if no
thermostat) to the ON position.
8.2.7
To shut down the appliance for short periods of time, turn the thermostat setting to the lowest temperature or
operate the ON/OFF switch (if no thermostat) to the OFF position.
8.2.8
To shut down the appliance for a period of time in excess of one week, press and turn the control knob
clockwise to the OFF position and turn off the gas supply at the gas isolation valve.