Page 21 of 24
7.14.4 When assembling a replacement reverberatory screen, ensure that it is positioned on the cross support, at the
controls end to prevent shorting of the flame sensor.
7.15
Emitter Assembly
7.15.1 Having disconnected the electrical and gas supplies from the appliance and lowered the appliance to the
ground, (see sections 6.7.3 and 6.7.4) place the appliance on a work bench and carry out the following
instructions.
7.15.2 Disconnect the grey flame sensor lead from the flame probe by gently pulling the connector, using pliers.
7.15.3 Disconnect the black HT ignition lead from the ignition spark electrode by gently pulling the plastic
shroud from the Raja connector of the electrode.
7.15.4 Remove the screws securing the reflector assembly to the flue collar panels and remove the reflector
assembly.
7.15.5 Place the appliance with the emitter surface facing upwards. Remove the M4 screws securing the flue collar
panels to the plenum body and remove the flue collar panels. Care should be taken to avoid damage to the
spark electrode and flame probe.
7.15.6 Slide out the reverberatory screen.
7.15.7 Remove the 1/4" UNC nuts and setscrews retaining the emitter assembly and reverberatory screen side rails
and end baffles to the plenum body. Lift off the reverberatory screen side rails and end baffles and carefully lift
our the emitter assembly.
7.15.8 Clean off any ceramic paper gasket material from the plenum body flanges and emitter assembly.
7.15.9 When assembling a replacement emitter assembly, new ceramic paper gasket material must be used to
provide a complete seal between the plenum body flanges and the emitter assembly.
7.16
Replacement Parts List
The following is a list of replacement parts that may be required during the life of the appliance.
Part
Part Number
Part
Part Number
Pilot Frame
1790
Control Valve (Spark)-Honeywell 4262240
Thermopile
1801
Control Valve (Spark)-S.I.T
4262585
Pilot Injector (LPG)
1901
Control Valve (Pilot)
4262241
Pilot Injector (NG)
1902
Emitter Assy SRP08
4262306
Pilot Reverb. Screen SRP08
4250567
Emitter Assy SRP15
4262307
Pilot Reverb. Screen SRP15
4250568
Emitter Assy SRP22
4262308
Pilot Reverb. screen SRP22
4250569
Emitter Assy SRP30
4262309
Reverb. Screen SRP08
4250589
Venturi Gasket
4262420
Reverb. Screen SRP15
4250590
Ceramic Paper Gasket
4262421
Reverb. Screen SRP22
4250591
Thermocouple
4262
Reverb. Screen SRP30
4250592
1/4" UNC Hex Nut s/s
4267925
Ignition Control (Honeywell)
4262196
1/4" UNC x 5/8" Setscrew S/S
4267926
Ignition Control (S.I.T.)
4262535
Spark Electrode
4262205
Flame Sensor
4262206
8.
Operating Instructions
8.1
Direct Burner Spark Ignition Models
.
8.1.1
Turn on the gas supply to the appliance.
8.1.2
Set any time switch or thermostats to demand heat.
8.1.3
Switch on the electrical supply to the appliance.
8.1.4
The burner should ignite within 25 seconds (Honeywell Control) or 10 seconds (S.I.T Control).