Command List

Function

Command

Exposition

Entering programming mode

     PPPPPP

PPPPPP: Master Code, (Default value: 123456)

 Exiting programming mode
 Exiting programming mode and enabling all device 

into arming status.

Including AR-725 (E-V2), WG Reader

Enabling each device into arming status.

           U

U

Enable target unit

 (

0=AR-725 (E-V2)

 , 

1=WG Reader

)

Node ID setting

00      NNN     MMM     AAA

NNN

Node ID,(001~254)

MMM

AR-725 (E-V2) Door Number,(001~255)

AAA

WG Reader Door Number,(001~255)

IP Address assign (Must power reset)

01      0     CCCCCCCCCCCC

default value = 192.168.1.127
CCCCCCCCCCCC = 192168001127
If set to 000.000.000.000 will enable DHCP otherwise 

will disable DHCP

01      1     255255255000

Netmask

01      2     192168001254

Gateway assign

Door relay time setting

02      U      TTT

U

Enable target unit (0=AR-725(E-V2) , 1=WG Reader)

TTT

Door relay time

000 (Output constantly)

001~600

1-600 Sec.

601~609

0.1~0.9Sec.

Alarm relay time setting

03      TTT

TTT

Alarm relay time

000 (Output constantly)

001~600

1~600

 

Sec.

Mode setting

04      M

M

4 (Mode 4)

M

8 (Mode 8)

Arming delay time setting

05      TTT

Base on second, range: 001~255

Alarm delay time setting

06      TTT

Base on second, range: 001~255

Master card setting

07      SSSSS      EEEEE

SSSSS-EEEEE

00000~15999

SSSSS= starting user address; EEEEE= ending user address

Auto-open zone setting

08      MW      NN      HHMMhhmm     
7123456H

M=AR-725(E-V2); W=WG Reader (0=disable; 1=enable)
NN

16 sets of auto-open zone (Range: 00~15)

HHMMhhmm=staring time to ending time
(e.g.: 08301200=08:30 to 12:00)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)

Master code settings

09      PPPPPPRRRRRR

PPPPPP= New master code
RRRRRR= Repeat the new master code

Suspend or delete tags

Suspend

10     SSSSS     EEEEE

    

:Suspend         :Delete

SSSSS= starting user address; EEEEE= ending user address

Delete

:  

10     SSSSS     EEEEE

Recover tag

11      SSSSS      EEEEE

SSSSS= starting user address; EEEEE= ending user address

Setting up Card or PIN mode by user address

12      UUUUU     PPPP

UUUUU= user address; PPPP=4-digit individual PWD
(Access mode: Card or PIN)

Setting up Card and PIN mode by user address

13      UUUUU     PPPP

UUUUU= user address; PPPP=4-digit individual PWD
(Access mode: Card and PIN)

Arming output setting

14      TTT

Base on 1ms, range:1~255, default value=10, 
Input 0= Timeless

Duress code setting

15      PPPP

PPPP

4-digit PWD (0001-9999)

Default value

0000

Card number modification

16      UUUUU     SSSSSCCCCCC

UUUUU

user address

SSSSS

5 digit site code ; CCCCC

5 digit card code

Arming PWD setting

17      PPPP

PPPP

4-digit PWD (0001-9999)

Default value

1234

Enabling or Disabling into arming status

Card+

NNNN

NNNN

Arming PWD

U

Enable target unit (0=AR-725(E-V2) , 1=WG Reader)

Enabling or Disabling each device into arming status.

Card

+

NNNN       U

Enabling all device into arming status.

Card+

NNNN

Disabling

 all device into arming status.

Card+

NNNN

Door open waiting time

18      U      TTT

U

Enable target unit

 (

0=AR-725(E-V2)

 , 

1=WG Reader

)

TTT=Door open waiting time:001~600;default value:15 sec.

Set the card by induction

19      UUUUU     QQQQQ

UUUUU

user address

QQQQQ=Card quantity(00001=Continuously inducting)

Reader additional setting

20      U      DDD

U

Enable target unit (0=AR-725(E-V2) , 1=WG Reader)

DDD=Function default value

9

9

9

Содержание AR-725

Страница 1: ...n key and screws accessories supplied Turn on the power and LED will light and beep will sound Use a screwdriver to screw the base F onto the wall Attach the water proof gasket to the body A1 and pull...

Страница 2: ...Color Description Anti Tamper Switch 1 Red N C 2 Orange COM 3 Yellow N O P5 Cable WireApplication Wire Color Description Power 1 Red DC 12V Output Security trigger signal 2 Purple Security trigger sig...

Страница 3: ...ontroller single tag or random numbered cards one by one Done e g 2 readom cards with user addresses No 100 and No 101 Access programming mode 19 00100 00001 Present the tags one by one Done Input 123...

Страница 4: ...plied to parking areas in order to prevent from multi entry with one card at a time or somewhere wants to monitor not only the access but also exit condition Door will keep opening after first man fla...

Страница 5: ...or illegal procedure 3 Door position abnormal Arming is enabled and the power is suddenly off then on Enable all devices Induct valid card Input 4 digit arming code Enable particular device Induct va...

Страница 6: ...s sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password...

Страница 7: ...7 days of week Sun Mon Tue Wed Thu Fri Sat Input value 0 disable 1 enable H Holiday Input value 0 disable 1 enable Master code settings 09 PPPPPPRRRRRR PPPPPP New master code RRRRRR Repeat the new mas...

Страница 8: ...value 1 19200 2 LED Panel 2 38400 3 Printer 3 57600 TTL port BAUD setting 38 DDD DDD 001 4800 bps DDD 065 9600 bps DDD 129 19200 bps Function Default Value 20 U DDD Default Value Function Option Valu...