SOYAL
ACCESS CONTROL SYSTEM
®
AR-725 (E-V2)
V130116
Firmware Upgrade
Get the upgrade software from SOYAL or our distributor and run “UdpUpdater” software
Update the firmware
[Please login the SOYAL web to download the new ISP Firmware.]
1. Input the Target Address and Port
2. [Load F/W] open the documents that have the new ISP Firmware
3. Click the new ISP Firmware and [Open] it
4. Click [Update Device] to start the firmware update
5. Till the screen shown [Firmware Update is Complete]
Execute the software
The software is within SOYAL CD or Login the
SOYAL web to downloads
1
2
5
4
3
Restoring Factory Settings
Reset all device parameters and user card data
Reset all user card data:
Access programming mode
→
29
29
Reset IP Setting:
Press
“IP Resent Button”
of main board for few seconds. (Reference to picture)
Reset all device parameters and user card data:
Access programming mode
→
29
29 9
Enable all devices:
Access programming mode
→
Enable particular device:
Access programming mode
→
U
Enable Arming status:
Disable Arming status:
Standby Mode
Standby Mode
Enter Program Mode
Card only
Card only
Card or Passcode
Card or Passcode
Card and Passcode
Card and Passcode
※
Factory default armingcode is: 1234. U=Reader unit (0=AR-725 (E-V2), 1=WG Reader).
H. Setting Up the Arming
Conditions:
1. Arming is enabled
2.Alarm system connected
Application:
1. Door open too long
: Door is open longer than door relay time plus door close time.
2. Force open
(Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal
: Arming is enabled and the power is suddenly off then on.
Enable all devices
Induct valid card
→
Input 4 digit
arming code
→
Enable particular device
Induct valid card
→
Input 4 digit
arming code
→
U or
Disable particular device
Induct valid card
→
Input 4 digit
arming code
→
U or
Input 5 digit user address
→
Input 4
digit pass code
→ →
Input 4 digits
arming code
→
or U
Induct valid card
→
Input 4 digit pass
code
→
→
Input 4 digits arming
code
→
or U
Disable all devices
Induct valid card
→
Input 4 digit
arming code
→
9
Input 5 digit user address
→
Input 4
digit pass code
→ →
Input 4 digits
arming code
→
or U
9
Induct valid card
→
Input 4 digit pass
code
→
→
Input 4 digits arming
code
→
or U
9
※
After operation as above, you will hear the long reminder sound,and wait until the
sound disappear then reset the power of the controller,the device will restore factory setting.
G. Lift control
Single floor
[e.g.] User address NO. 45 only can reach the elevator to the 24th floor:
27 00045 24
Access programming mode
→
27 UUUUU LL
UUUU=User Address LL=Floor number (01~64 floor)
Connect with
AR-401RO16B
to control floors which the user will be able to access. [BAUD9600]
Set
(G)
Floor
L
8
16
24
32
40
48
56
64
0
1
2
3
4
5
6
7
L
6
14
22
30
38
46
54
62
L
7
15
23
31
39
47
55
63
L
5
13
21
29
37
45
53
61
L
4
12
20
28
36
44
52
60
L
3
11
19
27
35
43
51
59
L
2
10
18
26
34
42
50
58
L
1
9
17
25
33
41
49
57
[e.g.] User address NO. 168 can reach only the 6th and 20th floor:
Access programming mode
→
21 00168 0 00100000
Multi floors
Access programming mode
→
21 UUUUU G LLLLLLLL
[UUUUU=User address G: 8 sets of lift control (Input: 0~7) LLLLLLLL:
8 floors setting (L=0=Disable, L=1=Enable)