Soyal AR-725 Скачать руководство пользователя страница 3

SOYAL

ACCESS CONTROL SYSTEM

®

AR-725 (E-V2)

V130116

   

EXIT

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

N.C.
N.O.

COM

CTL

12V

Door Contact

ALM

12V

GND

12V

GND

12V

GND

12V

GND

12V

GND

12V

GND

12V

GND

N.O.

GND

N.C.

N.O.

COM

PB

12V

GND

P1

P1

N.C.
N.O.
COM

CTL

12V

E

E

BZ

RLED
GLED

WG 0
WG 1

12V

GND

1

1

1

2

2

2

3

3

3

4

4

4

5

5

5

6

6

6

7

7

7

8

8

8

1
2
3
4
5
6

12V
GND
Exit Switch

12V
GND

12V
GND

12V

GND

12V

GND

12V

GND

PB

PB

COM

COM

N.O.

N.O.

P2

P1

P1

P1

BZ
RLED
GLED
Door Output
WG 0
WG 1
WG-DS
WG-PB

7
8

EXIT

1
2
3
4
5
6
7
8

1   2   3

N.C.
N.O.

COM

CTL
12V

GND

PB

12V

GND

12V
GND

N.O.

12V

GND

12V

GND

DDR

P1

P6

AR-721RB

4

12V

N.C.

EXIT

RTE

EXIT

1
2
3
4
5
6
7
8

12V
GND

12V

GND

PB

COM

N.C.

P1

EXIT

EXIT

    

Adding and Deleting Tag

Delete a Single Tag

Input      123456      (or Master Code)

 → 

10     SSSSS     EEEEE

[e.g.] Delete User Address: 00058

       

Access programming mode

 → 

10     00058     00058

9

9

Add Single Tag or Random tags

Input      123456      (or Master Code)

 → 

19     UUUUU     00001

     → 

Present the tag(s) with Controller 

(single tag or random numbered cards one by one)

 → 

Done

[e.g.] 2 readom cards with user addresses No. 100 and No. 101:

       

Access programming mode

 → 

19     00100     00001

     → 

Present the tags one by one

 → 

Done

Input      123456      (or Master Code)

 → 

19     UUUUU     QQQQQ

     → 

Present the tags 

(Present the tag with the 

lowest number

 first.)

 → 

OK

Add the Sequential tags

[e.g.] User Address NO.101 to NO.120 have 20 pcs of sequential tags:(62312~62332)

       

Access programming mode

 → 

19     00101     00120

     → 

Close Tag into RF Area

(only use the tag 

NO.62312

)

 → 

OK

Tag Information

SITE CODE

CARD CODE

SITE CODE

CARD CODE

Controller 

Controller 

Controller 

Reader

Controller 

RTE

RTE

RTE

RTE

RTE

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

POWER

12VDC

Connect to Electric Strike

Connect to Door Contact

Electric Strike

Electric Strike

Alarm

Relay Outpot Module 

Door Contact

Door Contact

Strengthen security with AR-721RB

If any fire emergency, the people can escape by press a switch to open all doors

Electric Bolt

Electric Bolt

Electric Bolt

Fire Emergency

Transistor

IN4007

Transistor

IN4007

Connect to Reader

Magnet Lock

Содержание AR-725

Страница 1: ...n key and screws accessories supplied Turn on the power and LED will light and beep will sound Use a screwdriver to screw the base F onto the wall Attach the water proof gasket to the body A1 and pull...

Страница 2: ...Color Description Anti Tamper Switch 1 Red N C 2 Orange COM 3 Yellow N O P5 Cable WireApplication Wire Color Description Power 1 Red DC 12V Output Security trigger signal 2 Purple Security trigger sig...

Страница 3: ...ontroller single tag or random numbered cards one by one Done e g 2 readom cards with user addresses No 100 and No 101 Access programming mode 19 00100 00001 Present the tags one by one Done Input 123...

Страница 4: ...plied to parking areas in order to prevent from multi entry with one card at a time or somewhere wants to monitor not only the access but also exit condition Door will keep opening after first man fla...

Страница 5: ...or illegal procedure 3 Door position abnormal Arming is enabled and the power is suddenly off then on Enable all devices Induct valid card Input 4 digit arming code Enable particular device Induct va...

Страница 6: ...s sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password...

Страница 7: ...7 days of week Sun Mon Tue Wed Thu Fri Sat Input value 0 disable 1 enable H Holiday Input value 0 disable 1 enable Master code settings 09 PPPPPPRRRRRR PPPPPP New master code RRRRRR Repeat the new mas...

Страница 8: ...value 1 19200 2 LED Panel 2 38400 3 Printer 3 57600 TTL port BAUD setting 38 DDD DDD 001 4800 bps DDD 065 9600 bps DDD 129 19200 bps Function Default Value 20 U DDD Default Value Function Option Valu...

Отзывы: