11
The following procedures shall be observed for goods transportation
:
①
Decelerate when approaching the goods area
;
②
Inspect safety condition around the stacking area
;
③
Adjust position of the truck, placing it in front of place where goods locate
;
④
Slowly start the truck, and insert fork arms to the bottom of goods as deeply as possible
;
⑤
Press the lifting button, raising forks to a position with a distance of over 40mm between bottom of the pallet
and ground
;
⑥
Start the truck and carry the goods to destination. Press lowering button and put the goods on the ground,
making the forks totally out of the bottom of the pallet. Then backward the truck slowly
;
Ⅴ.
Usage, maintenance and charge of storage battery
Schematic diagram of charging method
When it is necessary to conduct charging, please refer to the following operation methods
,
1. Pull down the general power switch
;
2. Connect the charging plug of storage battery to output connector
of charger
;
3. Then link the input connector of charger to AC power system
;
4. Turn on the charger, and it starts
to charge after several seconds
。
1 Initial charge
1
.
11 Initial charge shall be made for new battery, i.e. the first time charge. Clean up the surface of the
battery before the initial charge, and then check for damage to ensure reliable connection
。
1
.
2 Open gas cap
。
1
.
3When the charging equipment is able to operate normally, pour the sulfuric acid electrolyte with a
density of 1.260±0.005 (25℃) and a temperature of lower than 30℃ into the batteries. The electrolyte level
should be 15-25mm higher than the protective board. In order to reduce the temperature rise caused by
chemical reaction of the electrolyte and let the electrolyte fully penetrates into the pores of the polar plates and
the baffles, the batteries should be placed still for 3-4 hours, not exceeding 8 hours. The initial charging can only
be conducted when the electrolyte temperature reduces to below 35℃. (When necessary, the batteries can be
put into cold water for temperature reduction). After the still placement, if the electrolyte level reduces,
Warning
Hydrogen is aggregated in the battery box when charging. For this reason,
the charging condition shall be good ventilated. In avoidance of explosion and fire
disaster, open flame is forbidden
。