Safety cont.

• Do not expose power tools to rain or wet conditions. Water entering a 

   power tool can increase the risk of electric shock.

• Do not place Triggers in standing water.

• Plug into a (GFCI) ground fault interrupted circuit outlet only.

• Use a 10 gauge 20 Amp 120 Volt extension cord.

• Maintain proper care of power cords. Do not use the cord to carry the tool 

   or pull the plug from an outlet. Replace damaged cords immediately. 

   Damaged cords can increase the risk of electric shock.

• Do not use this tool near live circuits. Shut off and lock out power when 

   working near existing circuits.

Electric Shock Hazards

WARNING:

• Do not open or disassemble battery pack.

• Do not expose to fire or open flame.

• Do not mix batteries of varying sizes or chemistries or types.

• Do not puncture, deform, incinerate, or heat or use in environments 

   above 85°C or 194°F.  

FAILURE TO OBSERVE THESE WARNINGS CAN RESULT

IN SEVERE INJURY OR DEATH.

Battery Pack

WARNING:

Purpose Of This Manual

This instruction manual is intended to familiarize personnel with the 

safe operation for the Southwire

 Triggers

®

 Wireless Safety Switch 

System. Keep this manual available to all personnel. Replacement 

manuals are available upon request at no charge at www.southwire-

tools.com.

 

Содержание 59713201

Страница 1: ...outhwire Triggers Wireless Safety Switch System TSS 01 Read and understand all of the instructions and safety information in this manual before operating or servicing this tool FAILURE TO OBSERVE THES...

Страница 2: ...ontents Description 2 Safety 3 4 Purpose of this Manual 4 Identification 5 10 Pairing Instructions 11 System Operation 12 14 Battery Charging and System Storage 14 Parts List 15 Specifications 15 Warr...

Страница 3: ...the puller motor to operate Any time either foot pedal is released or the stop button on the hand held unit is pressed the puller motor will stop The Triggers Master and Remote units may also be used...

Страница 4: ...uence of drugs alcohol or medication Always follow operating procedures Avoid accidental starting Make sure switch is off before plugging it in Do not operate this tool with a puller while wearing loo...

Страница 5: ...its Shut off and lock out power when working near existing circuits Electric Shock Hazards WARNING Do not open or disassemble battery pack Do not expose to fire or open flame Do not mix batteries of v...

Страница 6: ...Vac Low Indicator Light 6 Linked Indicator Light 7 Master Unit Stand Alone Indicator Light 8 Stop Indicator Light 9 Ready Indicator Light 10 Running Indicator Light 11 Antenna 12 Signal Strength Indic...

Страница 7: ...P LIGHT RED Indicates that pull is at complete stop FLASHING STOP FORCED STOP Stop has been pressed on hand held unit READY LIGHT AMBER Indicates that one pedal is depressed and there is no forced sto...

Страница 8: ...ht 5 Vac Low Indicator Light 6 Linked Indicator Light 7 Master Unit Stand Alone Indicator Light 8 Stop Indicator Light 9 Ready Indicator Light 10 Running Indicator Light 11 Antenna 12 Signal Strength...

Страница 9: ...es that pull is at complete stop FLASHING STOP FORCED STOP Stop has been pressed on hand held unit READY LIGHT AMBER Indicates that one pedal is depressed and there is no forced stop condition present...

Страница 10: ...icator Light 3 Charge Indicator Light 4 Linked Indicator Light 5 Stand Alone Indicator Light 6 Stop Indicator Light 7 Ready Indicator Light 8 Running Indicator Light 9 Antenna 10 Signal Strength Indic...

Страница 11: ...it is linked to the system master remote STAND ALONE LIGHT BLUE Indicates that either master or remote unit is in stand alone mode STOP LIGHT RED Indicates that pull is at complete stop READY LIGHT AM...

Страница 12: ...the number of LED s lit up on the Amperage Draw Indicator 8 Once all desired units are paired press the PAIR button on the Master Unit to complete the pairing process Pairing Instructions NOTE If add...

Страница 13: ...econds 5 Once all units are accounted for Press the pedal on the master unit and all units LINKED light will come on BEFORE USING THE SYSTEM TO PULL CABLE VERIFY THAT ALL UNITS FUNCTION AS OUTLINED BE...

Страница 14: ...gers Master foot pedal 7 Pushing down on the Triggers Master foot pedal 11 will start the puller s motor Lifting off of the Foot Pedal will stop the puller s motor REMOTE UNIT AS STAND ALONE FOOT SWIT...

Страница 15: ...nths Before storage all battery operated units in the system should be charged to approximately 60 percent Case provides for quick and easy recharging Place Hand Held units in their respective docking...

Страница 16: ...SET MASTER PEDAL REMOTE PEDAL HAND HELD UNIT HAND HELD DOCKING STATION DOCKING STATION POWER SUPPLY CARRYING CASE BATTERY 7 PLUG POWER STRIP 1 Master Unit 2 Remote Unit 3 2 Hand Held Units 4 2 Dockin...

Страница 17: ...s ignee This 5 Year Limited Warranty is not transferrable to or enforce able by any person other than the product s original end user One Year Limited Warranty on Rope Blades Dies Draw Studs Grips and...

Страница 18: ...SOUTHWIRE WILL NOT BE LIABLE FOR ANY IN CIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES FOR ANY BREACH OF THIS LIMITED LIFETIME WAR RANTY Some states do not allow the exclusion or limitati...

Страница 19: ...he original date of delivery must be set forth on the Product Return Authorization Form 3 Southwire will cover standard freight charges FedEx Ground rate incurred in connection with products that Sout...

Страница 20: ...manual Contents Made in USA Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2016 Southwire Company LLC All rights reserved southwiretools com 1 855 SW T00LS Toll F...

Отзывы: