AMPERAGE DRAW INDICATOR AND LOW VAC INDICATOR
The amperage Draw Indicator is scaled to read from 0 to 20 Amps. This is
not a safety feature and is to be used for reference only. The unit itself does
not provide any over amperage protection.
LOW VAC indicator light indicates when the line voltage has dropped
below the minimum recommended input voltage. This is not a safety fea-
ture and is to be used for reference only. The unit itself does not provide
any under voltage protection.
BATTERY CHARGING AND SYSTEM STORAGE
Both the Remote Unit and the Hand Held Units contain Li-Ion battery
packs that require periodic freshening charges at least once every 6
months. Before storage, all battery-operated units in the system should be
charged to approximately 60 percent. Case provides for quick and easy
recharging. Place Hand Held units in their respective docking stations, Plug
Remote foot switch into power strip. Plug power strip into outlet and allow
all components to charge in the case.
REMOTE PEDAL
1. Plug pedal into outlet. Battery meter will show approximate level of
charge. Once charging is complete, the battery meter will go solid.
HAND HELD UNIT
1. Plug supplied 9V power supply into docking station.
2. Plug 9V power supply in to outlet.
3. Place Hand Held unit into docking station. While in the docking station,
the “CHARGE” light will illuminate and the battery meter will flash the
approximate level of charge. Once charging is complete the battery
meter will go solid and “CHARGE” light will turn off.
Operation cont.