Southwire 59713201 Скачать руководство пользователя страница 13

Before using the Triggers

®

 system all battery powered units should be 

fully charged

1. Turn on Master Unit by pressing the power button (1). Power light    

    (4) will indicate power to the unit.
2. Turn on the Remote Unit by pressing the Power button (1). Power  

    light will indicate power to the unit.
3. Turn on the Hand Held Units by pressing the Power button (1).  

    Power light will indicate power to the unit.
4. The Master unit will scan for Remote or Hand Held units. As they  

    are found, an LED on the amperage indicator will light up and the  

    Signal Strength Indicator on the corresponding Remote or Hand  

    Held Unit will display signal strength. This process can take several  

    seconds.
5. Once all units are accounted for, Press the pedal on the master unit  

    and all units’ “LINKED” light will come on.

BEFORE USING THE SYSTEM TO PULL CABLE VERIFY THAT ALL UNITS 

FUNCTION AS OUTLINED BELOW

• Prior to engaging the foot pedals, the indicator light will show 

“STOP”.

• If both pedals are engaged the “RUNNING” indicator will be on and  

  the output to the feeder or puller’s motor will be turned on.

• If either pedal is lifted the puller will stop and the indicator light will  

  read “READY”.

• If stop button is pressed on any Hand Held unit, the puller will stop  

  and the “STOP” light will flash on the Master, Remote and Hand unit  

  on which it was pressed. This is a “forced stop”. The other Hand  

  Held units will have a solid “STOP” light. To clear this condition hold  

  down the stop button on the unit on which it was pressed until the  

  “STOP” light quits flashing.

Operation

Содержание 59713201

Страница 1: ...outhwire Triggers Wireless Safety Switch System TSS 01 Read and understand all of the instructions and safety information in this manual before operating or servicing this tool FAILURE TO OBSERVE THES...

Страница 2: ...ontents Description 2 Safety 3 4 Purpose of this Manual 4 Identification 5 10 Pairing Instructions 11 System Operation 12 14 Battery Charging and System Storage 14 Parts List 15 Specifications 15 Warr...

Страница 3: ...the puller motor to operate Any time either foot pedal is released or the stop button on the hand held unit is pressed the puller motor will stop The Triggers Master and Remote units may also be used...

Страница 4: ...uence of drugs alcohol or medication Always follow operating procedures Avoid accidental starting Make sure switch is off before plugging it in Do not operate this tool with a puller while wearing loo...

Страница 5: ...its Shut off and lock out power when working near existing circuits Electric Shock Hazards WARNING Do not open or disassemble battery pack Do not expose to fire or open flame Do not mix batteries of v...

Страница 6: ...Vac Low Indicator Light 6 Linked Indicator Light 7 Master Unit Stand Alone Indicator Light 8 Stop Indicator Light 9 Ready Indicator Light 10 Running Indicator Light 11 Antenna 12 Signal Strength Indic...

Страница 7: ...P LIGHT RED Indicates that pull is at complete stop FLASHING STOP FORCED STOP Stop has been pressed on hand held unit READY LIGHT AMBER Indicates that one pedal is depressed and there is no forced sto...

Страница 8: ...ht 5 Vac Low Indicator Light 6 Linked Indicator Light 7 Master Unit Stand Alone Indicator Light 8 Stop Indicator Light 9 Ready Indicator Light 10 Running Indicator Light 11 Antenna 12 Signal Strength...

Страница 9: ...es that pull is at complete stop FLASHING STOP FORCED STOP Stop has been pressed on hand held unit READY LIGHT AMBER Indicates that one pedal is depressed and there is no forced stop condition present...

Страница 10: ...icator Light 3 Charge Indicator Light 4 Linked Indicator Light 5 Stand Alone Indicator Light 6 Stop Indicator Light 7 Ready Indicator Light 8 Running Indicator Light 9 Antenna 10 Signal Strength Indic...

Страница 11: ...it is linked to the system master remote STAND ALONE LIGHT BLUE Indicates that either master or remote unit is in stand alone mode STOP LIGHT RED Indicates that pull is at complete stop READY LIGHT AM...

Страница 12: ...the number of LED s lit up on the Amperage Draw Indicator 8 Once all desired units are paired press the PAIR button on the Master Unit to complete the pairing process Pairing Instructions NOTE If add...

Страница 13: ...econds 5 Once all units are accounted for Press the pedal on the master unit and all units LINKED light will come on BEFORE USING THE SYSTEM TO PULL CABLE VERIFY THAT ALL UNITS FUNCTION AS OUTLINED BE...

Страница 14: ...gers Master foot pedal 7 Pushing down on the Triggers Master foot pedal 11 will start the puller s motor Lifting off of the Foot Pedal will stop the puller s motor REMOTE UNIT AS STAND ALONE FOOT SWIT...

Страница 15: ...nths Before storage all battery operated units in the system should be charged to approximately 60 percent Case provides for quick and easy recharging Place Hand Held units in their respective docking...

Страница 16: ...SET MASTER PEDAL REMOTE PEDAL HAND HELD UNIT HAND HELD DOCKING STATION DOCKING STATION POWER SUPPLY CARRYING CASE BATTERY 7 PLUG POWER STRIP 1 Master Unit 2 Remote Unit 3 2 Hand Held Units 4 2 Dockin...

Страница 17: ...s ignee This 5 Year Limited Warranty is not transferrable to or enforce able by any person other than the product s original end user One Year Limited Warranty on Rope Blades Dies Draw Studs Grips and...

Страница 18: ...SOUTHWIRE WILL NOT BE LIABLE FOR ANY IN CIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES FOR ANY BREACH OF THIS LIMITED LIFETIME WAR RANTY Some states do not allow the exclusion or limitati...

Страница 19: ...he original date of delivery must be set forth on the Product Return Authorization Form 3 Southwire will cover standard freight charges FedEx Ground rate incurred in connection with products that Sout...

Страница 20: ...manual Contents Made in USA Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2016 Southwire Company LLC All rights reserved southwiretools com 1 855 SW T00LS Toll F...

Отзывы: