BURNER SPECIFICATIONS
Burner Model:
Wayne P250-EP
Firing Capacity:
Maximum Input 75,000 BTU/HR, on Model SPX-300
Fuels:
Natural and L.P. Gases
Electrical:
120 V.A.C., 60 hz, 1 ph
Orifice Sizes: Model SPX-300
Natural Gas - #19 (.166)
L.P. Gas - #37 (.104)
NOTE:
Orifice and valve setting must correlate with type of gas being
supplied.
Gas Supply Line Pressure:
Natural - 4.5” W.C. Minimum L.P. - 11.0” W.C. Minimum
10.0” W.C Maximum 13.0” W.C. Maximum
MANIFOLD PRESSURE:
GAS VALVE:
Control Knob must be
ON.
WIRING DIAGRAM FOR GAS BURNER P-250EP THERMOCOUPLE PILOT LOCATION
20
Natural - 3.0” W.C. Minimum L.P. - 9.5” W.C. Minimum
3.5” W.C. Maximum 10.0” W.C. Maximum