4. Repeat Step 3 to adjust the LOW to 325°F (163°C) and MEDIUM to 335°F (168°C) potentiometers.
Always allow the oven to cycle twice after adjustment to confirm accuracy. After completion of
calibration, remove the oven thermometer, and reinstall the side panel and insulation along with any
other steps necessary to return the unit to service.
LOW
MEDIUM
HIGH