ADJUSTMENTS
ACCESS TO SERVICEABLE PARTS:
Some serviceable parts are only accessible by removing the body side and/or front. The following diagram depicts the
procedure to follow should this be necessary.
A. Body side "B" is fastened with (2) slotted hex head sheet metal screws "S, and F," for left side, or "S, and Fa" for right
side, as shown. Remove screws and slide body side "B" rearward and up. It is not necessary to remove the main front
when removing the body sides, provided installation clearances are adequate.
B. The main front "M" is fastened with (6) slotted hex head sheet metal screws "F,, F,, Fa, F<, F,, and Fg, as shown. Valve
knob is slipped on and fastened with a set screw. Upon removing these, the main front can now be pulled forward and
removed. ("A" models must have arm knob removed.)
There may be times when it will be easier to perform service with the broiler section removed from the riser or wall. This may
be accomplished by:
1. Shut off gas supply to broiler.
2. Disconnect gas supply line.
3. Remove bottom cover by removing (4) slotted hex head sheet metal screws — 2 on each side.
4. Remove (2) slotted hex head sheet metal screws from bottom, located on underside of broiler.
5. Remove (3) slotted hex head sheet metal screws from top of hanger.
6. Lift broiler section straight up until rear hanger clears top of riser or wall bracket.
To Reinstall Broiler:
1. Lift broiler back into position, line up holes for (3) screws and fasten same.
2. Install (2) screws at bottom sides.
3. Reconnect gas supply line.
4. After turning on gas supply, check gas connection and any other piping which was affected by the repair, with soapy
water to be positive there are no gas leaks.
5. Reinstall bottom cover with (4) screws.
COMPACT INFRA-RED BROILERS
SECTION THREE — SERVICE
PAGE 2
Litho in U.S.A.
Rev. 7-91