SYSTEM OPERATIONS
The system has two standard run modes – Run and Standby. When the
power switch is turned on, the controller will automatically determine which
mode to enter and will display the current run mode on the screen – “Run” in
Green and “StdbY” in Yellow. The layout of the controller can be seen on the
next page.
System Status
“Run” mode is when the FPS-650 and FPS-1250 is producing nitrogen and
feed it to the storage tank. The system will automatically enter “Standby”
mode when the tank is fully pressurized (65-75 psig). It will remain in
“Standby” mode until the tank pressure falls 7-10 psig.
Figure 1: Controller Display