background image

 

 

                                                                                                      South-Tek Systems 

Version:

 0

 

Revision Date: 6/29/18

                                                                                                           

Page 16 of 18 

APPENDIX A: WARRANTY 

The 

BrewBlast™  110CPH

  System  is  warrantied  against  any  defects  in 

workmanship  and  materials  for  12  months  (or  1000  hours)  from  the  date  of 
shipment  from  South-Tek  Systems,  whichever  comes  first.    The  purchaser  has 
the  liability  to  ensure  that  the  system  is  fully  inspected  upon  delivery  and  shall 
contact  the  appropriate  shipping  company  to  make  any  claims  on  damaged 

goods  due  to  transit  within  that  shipping  company’s  policies.    If  the  system  is 

received  with  defects  that  are  not  due  to  shipping,  a  written  claim  should  be 
submitted to South-Tek Systems within 1 week of receiving the shipment.  South-
Tek Systems can deny all other claims at their discretion. 
 
All warranty work shall be done at a South-Tek System facility or at a 

BrewBlast™ 

110CPH  Authorized  Service  Center.  Only  factory  trained  and  authorized 
personnel  are  covered  under  warranty.  Any  part  that  is  returned  /  repaired  / 
replaced  under  warranty  may  be  remanufactured  or  changed  to  a  different 
specific

ation  at  the  factory’s  option. 

Any  work  performed  by  an  unauthorized 

person/company  or  usage  of  non-factory  parts,  may  void  all  warranties  to  the 
product.  

 

 
Any  item  not  manufactured  by  South-Tek  may  carry  its  own  warranty  from  its 
manufacturer and will be warrantied by that manufacturer.  All parts that need to 
be  returned  should  be  announced.    Any  item(s)  that  is  returned  to  South-Tek 
Systems without an RMA number (return authorization number)  may  be denied 

and  returned  to  the  sender.    Contact  the  factory  for  RMA  #’s,  prior  to  return 

shipment. 
 
South-Tek  Systems  is  not  liable  for  damages  caused  by  normal  wear  and  tear, 
water, fire, erosion, corrosion, explosion, misuse, oil/gas vapors or unauthorized 
modifications.  South-Tek Systems is also not liable for any losses, damages, or 
cost  of  delays,  including  incidental  or  consequential  damages.    There  are  no 
warranties  or  guarantees,  expressed  or  implied,  including  the  warranties  of 
merchantability  or  fitness  for  a  particular  purpose  or  use,  other  than  those 
warranties expressed herein.   
 
For Claims, contact South-Tek Systems LLC at: 

Tel: (888) 526-6284    
Fax: (910) 332-4178  
Email

[email protected]

 

Or write to: 
South-Tek Systems, Warranty Claims,  
2940 Orville Wright Way,  

Содержание BREW BLAST 110CPH

Страница 1: ...The Leader in Nitrogen Generation Technology 110CPH Quick Start Guide Version 0 06 29 2018 2020 ...

Страница 2: ...BrewBlast 110CPH Specifications Nitrogen Purity 99 7 Installation Lockable Swivel Caster Wheels Display Hours Run Standby Filter Alarm BlastOffTM N Storage Pressure 60 90 PSIG Cabinet Port Connections Industrial Quick Coupler with 1 4 MNPT Plug Electrical 110V 60Hz 1Phase 10A Fuse Compressor Integral Oil Free Ambient Temperature 40 to 90 F Noise Level dbA 85 dbA Size 20 L x 9 W x 26 H Cabinet Dime...

Страница 3: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 3 of 18 Notes ...

Страница 4: ...1 3 Important Information 5 2 SAFETY GUIDELINES 6 2 1 General 6 3 INITIAL START UP 7 3 1 Electrical Connections 7 3 2 Nitrogen Drain Connections 8 3 3 Turning on the Generator for the First Time 9 3 4 Starting Stopping 10 4 SYSTEM OPERATION 11 4 1 Instructions 11 4 2 Alarms and Alarm Indicator Lights 11 5 SYSTEM MAINTENANCE 13 ...

Страница 5: ...d shelf life The N2 is generated by our membrane technology where compressed air is forced through a separation media and O2 is exhausted to atmosphere and N2 is allowed to pass through to process 1 2 AUDIENCE This manual is intended for Installer Restaurant Bar Operator Supervisory Staff and should be read in its entirety prior to operation Please contact your local provider for any operation and...

Страница 6: ...n of the nitrogen generator Blocking vents can cause excess heat to build in the nitrogen generator cabinet All personnel involved with installation operations and maintenance of the BrewBlast 110CPH must follow safe working practices OSHA and local health safety code regulations during the installation operation and maintenance of the unit Warning This guide must be read in its entirety prior to ...

Страница 7: ...ey can be used to connect to an audible or visual alarm indicator or run to a building management device These contacts are rated for a maximum of 1A at 5 27VDC 5 240VAC Follow local and site regulations when wiring these connections The yellow wire acts as the common which will supply power to the NO or NC depending on alarm status If an alarm is triggered including BlastOff filter replacement an...

Страница 8: ...sleeve on the nitrogen outlet quick coupler while pushing the quick coupler plug into the coupler Once in place release the quick coupler sleeve to lock the plug into the coupler The condensate drain connection is a OD push to connect fitting this fitting can be connected to an external drain to drain off the water accumulated in the filter bowls The filter bowls drain automatically when enough wa...

Страница 9: ...oint the power switch should be illuminated designating the system is operating and the generator will start filling the internal storage tank It is suggested that the system plumbing leading to the cold brew system be purged with the nitrogen being generated in the initial start up for at least 15 minutes to ensure the best purity of nitrogen for pouring Watch the system fill and fix any leaks de...

Страница 10: ...illuminated and the generator will be operating normally The system has two main run modes Run and Standby When the green Operate power switch is turned on and illuminated the internal controller will automatically determine which mode to enter If the BrewBlast is in run mode the standby light will be off and the nitrogen generator will be filling the storage tank with nitrogen If the BrewBlast is...

Страница 11: ...his manual The system is design for 24 hour operation but routine maintenance on the filters must be performed See section System Maintenance for detail maintenance instructions 4 2 ALARMS AND ALARM INDICATOR LIGHTS Filter Alarm All BrewBlast 110CPH comes standard with a Filter Alarm notification The Alarm indicator light will illuminate continuously when the filter change is overdue It is recomme...

Страница 12: ...it Once a leak has been detected the BlastOff illuminates the BlastOff light in red on the control panel and shuts down the BrewBlast 110CPH until the problem has been remedied and the alarm has been reset To reset the BlastOff simply turn off the BrewBlast 110CPH using the green toggle switch and turn it back on Never reset repeatedly if the BlastOff goes off daily there is a real potential issue...

Страница 13: ...button Annual Filter replacement kit part FRP 001 Air Intake Filter The integrated air compressor has an air intake filter mounted on top It is design to prevent particles from entering into the compressor housing and damaging internal components This filter needs to be replaced once per year or every 1000 hours whichever comes first To do so remove the air intake filter cap by twisting it clockwi...

Страница 14: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 14 of 18 clean dry cloth to clean the filter enclosure before installing the new element ...

Страница 15: ...eplace the old O rings with the ones provided in the kit 5 Pull the black plastic element holder out of the filter bowl Carefully twist the two sides of the black plastic cover apart and pull out the white particulate filter element Install the new element in the reverse order 6 The coalescing element can be removed by turning it counter clockwise by hand install the new element in the reverse ord...

Страница 16: ...o a different specification at the factory s option Any work performed by an unauthorized person company or usage of non factory parts may void all warranties to the product Any item not manufactured by South Tek may carry its own warranty from its manufacturer and will be warrantied by that manufacturer All parts that need to be returned should be announced Any item s that is returned to South Te...

Страница 17: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 17 of 18 Wilmington NC 28405 ...

Страница 18: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 18 of 18 Last Page ...

Отзывы: