Particulate and Coalescing Filter 
The particulate and coalescing filter after the air compressor is designed to 
capture  particulate  and  moisture  prior  to  entering  the  rest  of  the  system. 
These  filters  need  to  be  replaced  once  per  year  or  every  1000  hours, 
whichever comes first. To do so,  

1.

 

Make sure there is no pressure on the filter bowls. The gauge on the 
filter assembly will read 0 PSIG to indicate that there is no pressure 
on the bowl. 

2.

 

Unscrew the filter bowls by turning them counter-clockwise. 

3.

 

Once the filter bowls have been removed, rinse any debris out of the 
bowls with warm water.  

4.

 

Dry the bowls with a clean dry cloth and replace the old O-rings with 
the ones provided in the kit.  

5.

 

Pull the black plastic element holder out of the filter bowl. Carefully 
twist the two sides of the black plastic cover apart and pull out the 
white particulate filter element. Install the new element in the reverse 
order. 

6.

 

The  coalescing  element  can  be  removed  by  turning  it  counter-
clockwise by hand; install the new element in the reverse order.  

7.

 

Once  both  elements  have  been  replaced,  bowls  have  been  cleaned 
and  O-rings  replaced,  the  bowls  can  be  screwed  back  in  to  their 
corresponding filter housings. 

 
 
Once  all  the  filters  have  been 
replaced, press and hold the filter 
reset button on the  control panel 

until  the  “Alarm”  indicator  light 

blinks  confirming  the  1000-hour 
run timer has been reset. Put the 
front  cover  back  on  the  cabinet 
and  power  up  the  nitrogen 
generator.  Once  powered  up,  the 

BrewBlast™  110CPH

  will  be 

producing nitrogen when needed. 
 

 

 

Содержание BREW BLAST 110CPH

Страница 1: ...The Leader in Nitrogen Generation Technology 110CPH Quick Start Guide Version 0 06 29 2018 2020 ...

Страница 2: ...BrewBlast 110CPH Specifications Nitrogen Purity 99 7 Installation Lockable Swivel Caster Wheels Display Hours Run Standby Filter Alarm BlastOffTM N Storage Pressure 60 90 PSIG Cabinet Port Connections Industrial Quick Coupler with 1 4 MNPT Plug Electrical 110V 60Hz 1Phase 10A Fuse Compressor Integral Oil Free Ambient Temperature 40 to 90 F Noise Level dbA 85 dbA Size 20 L x 9 W x 26 H Cabinet Dime...

Страница 3: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 3 of 18 Notes ...

Страница 4: ...1 3 Important Information 5 2 SAFETY GUIDELINES 6 2 1 General 6 3 INITIAL START UP 7 3 1 Electrical Connections 7 3 2 Nitrogen Drain Connections 8 3 3 Turning on the Generator for the First Time 9 3 4 Starting Stopping 10 4 SYSTEM OPERATION 11 4 1 Instructions 11 4 2 Alarms and Alarm Indicator Lights 11 5 SYSTEM MAINTENANCE 13 ...

Страница 5: ...d shelf life The N2 is generated by our membrane technology where compressed air is forced through a separation media and O2 is exhausted to atmosphere and N2 is allowed to pass through to process 1 2 AUDIENCE This manual is intended for Installer Restaurant Bar Operator Supervisory Staff and should be read in its entirety prior to operation Please contact your local provider for any operation and...

Страница 6: ...n of the nitrogen generator Blocking vents can cause excess heat to build in the nitrogen generator cabinet All personnel involved with installation operations and maintenance of the BrewBlast 110CPH must follow safe working practices OSHA and local health safety code regulations during the installation operation and maintenance of the unit Warning This guide must be read in its entirety prior to ...

Страница 7: ...ey can be used to connect to an audible or visual alarm indicator or run to a building management device These contacts are rated for a maximum of 1A at 5 27VDC 5 240VAC Follow local and site regulations when wiring these connections The yellow wire acts as the common which will supply power to the NO or NC depending on alarm status If an alarm is triggered including BlastOff filter replacement an...

Страница 8: ...sleeve on the nitrogen outlet quick coupler while pushing the quick coupler plug into the coupler Once in place release the quick coupler sleeve to lock the plug into the coupler The condensate drain connection is a OD push to connect fitting this fitting can be connected to an external drain to drain off the water accumulated in the filter bowls The filter bowls drain automatically when enough wa...

Страница 9: ...oint the power switch should be illuminated designating the system is operating and the generator will start filling the internal storage tank It is suggested that the system plumbing leading to the cold brew system be purged with the nitrogen being generated in the initial start up for at least 15 minutes to ensure the best purity of nitrogen for pouring Watch the system fill and fix any leaks de...

Страница 10: ...illuminated and the generator will be operating normally The system has two main run modes Run and Standby When the green Operate power switch is turned on and illuminated the internal controller will automatically determine which mode to enter If the BrewBlast is in run mode the standby light will be off and the nitrogen generator will be filling the storage tank with nitrogen If the BrewBlast is...

Страница 11: ...his manual The system is design for 24 hour operation but routine maintenance on the filters must be performed See section System Maintenance for detail maintenance instructions 4 2 ALARMS AND ALARM INDICATOR LIGHTS Filter Alarm All BrewBlast 110CPH comes standard with a Filter Alarm notification The Alarm indicator light will illuminate continuously when the filter change is overdue It is recomme...

Страница 12: ...it Once a leak has been detected the BlastOff illuminates the BlastOff light in red on the control panel and shuts down the BrewBlast 110CPH until the problem has been remedied and the alarm has been reset To reset the BlastOff simply turn off the BrewBlast 110CPH using the green toggle switch and turn it back on Never reset repeatedly if the BlastOff goes off daily there is a real potential issue...

Страница 13: ...button Annual Filter replacement kit part FRP 001 Air Intake Filter The integrated air compressor has an air intake filter mounted on top It is design to prevent particles from entering into the compressor housing and damaging internal components This filter needs to be replaced once per year or every 1000 hours whichever comes first To do so remove the air intake filter cap by twisting it clockwi...

Страница 14: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 14 of 18 clean dry cloth to clean the filter enclosure before installing the new element ...

Страница 15: ...eplace the old O rings with the ones provided in the kit 5 Pull the black plastic element holder out of the filter bowl Carefully twist the two sides of the black plastic cover apart and pull out the white particulate filter element Install the new element in the reverse order 6 The coalescing element can be removed by turning it counter clockwise by hand install the new element in the reverse ord...

Страница 16: ...o a different specification at the factory s option Any work performed by an unauthorized person company or usage of non factory parts may void all warranties to the product Any item not manufactured by South Tek may carry its own warranty from its manufacturer and will be warrantied by that manufacturer All parts that need to be returned should be announced Any item s that is returned to South Te...

Страница 17: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 17 of 18 Wilmington NC 28405 ...

Страница 18: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 18 of 18 Last Page ...

Отзывы: