South-Tek Systems
Version:
0
Revision Date: 6/29/18
Page 10 of 18
•
After the nitrogen storage tank is depleted down to the cut-in
pressure (~60 PSIG) the generator will turn back on and refill the
system.
3.4
STARTING & STOPPING
•
To
start
the
generator simply push the green
power switch on the front of the
generator to the ON(up) position.
Note: On startup the generator
will have a 12 second delay
before
the
compressor
operates. This is designed to
prevent
damage
to
the
compressor.
•
At this point the
power switch will be illuminated
and the generator will be
operating normally.
•
The system has
two main run modes
–
Run and
Standby.
When
the
green
(Operate) power switch is turned on and illuminated, the internal
controller will automatically determine which mode to enter.
•
If the BrewBlast
™
is in run mode, the standby light will be off and the
nitrogen generator will be filling the storage tank with nitrogen.
•
If the BrewBlast
™
is in standby mode, the standby light will be
illuminated; the nitrogen generator will be off and waiting until the
storage tank pressure drops the cut-in pressure to turn back on.
•
If the
BrewBlast™ 110CPH
runs continuously for more than 9 hours,
the BlastOff Alarm will shut down the generator (see:
for more
details)
Содержание BREW BLAST 110CPH
Страница 1: ...The Leader in Nitrogen Generation Technology 110CPH Quick Start Guide Version 0 06 29 2018 2020 ...
Страница 3: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 3 of 18 Notes ...
Страница 17: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 17 of 18 Wilmington NC 28405 ...
Страница 18: ...South Tek Systems Version 0 Revision Date 6 29 18 Page 18 of 18 Last Page ...