South Bend Tools
For Machines Mfd. Since 10/21
Model SB1118
-15-
P R E P A R A T I O N
10.
Close electrical box, and replace access panel
removed in Step 2.
11.
Remove front access panel and motor access
panel, and rewire main motor and table
motor for 440V operation (refer to motor
wiring diagrams on Page 65).
12.
Replace access panels removed in Step 11.
Note: If the diagram included on the motor
conflicts with the one in this manual, the
motor may have changed since the manual
was printed. Use the diagram provided on
the motor.
8.
Remove cutterhead overload relay (see
Figure 11) and replace with SDE RA-30
overload relay. Set amperage dial to 18.5A.
9.
Remove table overload relay (see Figure 11)
and replace with SDE RA-20 overload relay.
Set amperage dial to 1.2A.
6.
Open electrical box and locate transformer
(see Figure 9).
7.
Move R wire from 220V terminal to 440V
terminal (see Figure 10).
Figure
Figure 10. Moving R wire to 440V terminal.
. Moving R wire to 440V terminal.
220V 440V
0V
0V
24V
220V
T
R
Figure
Figure 9. Location of transformer inside electrical box.
. Location of transformer inside electrical box.
Transformer
Transformer
Figure
Figure 11. Location of cutterhead and table overload
. Location of cutterhead and table overload
relays.
relays.
Cutterhead
Cutterhead
OL Relay
OL Relay
Table
Table
OL Relay
OL Relay
Содержание SB1118